SAC-3
3 m distance for small products.
We build semi-anechoic chambers with absorber-lined walls and ceiling and a reflective floor for CE and certification testing of electronic products.
In a semi-anechoic chamber the walls and ceiling are covered with signal-absorbing material, while the floor is metal. This setup imitates outdoor product testing indoors.
Most of the emission and immunity tests required for CE and similar certifications are done in these chambers. They are classed as SAC-3, SAC-5 and SAC-10 by test distance.
No waiting in an external lab's queue.
The product is sent to testing ready.
The room is tested to the standard.
Emission and immunity together.
3 m distance for small products.
5 m distance for mid-size products.
10 m distance for large equipment.
Values are defined per project. We give the exact figures in writing in the quote after the site survey.
Industries where it is used
| Test distance | 3 m, 5 m or 10 m |
|---|---|
| Frequency range | 30 MHz – 18 GHz (depending on absorber selection) |
| Site validation | CISPR 16-1-4 (NSA, SVSWR) |
| Equipment | Turntable, antenna mast, filter |
| Standards | CISPR 32, EN 55032, IEC 61000-4-3 |
A semi-anechoic chamber exists to reproduce the results of an open-area test site indoors. Whether it actually does is proven by site validation measurements to CISPR 16-1-4; until they're done, the chamber can't be accepted as a test site.
Between 30 MHz and 1 GHz, normalized site attenuation (NSA) is measured and must stay within ±4 dB of the theoretical value. Above 1 GHz the SVSWR method is used, and the result must not exceed 6 dB. For immunity testing, field uniformity is calibrated to IEC 61000-4-3. These measurements are carried out by an independent accredited body, and we hand over the chamber with its reports.
30 MHz – 1 GHz, ±4 dB tolerance.
1–18 GHz, 6 dB limit.
16-point grid to IEC 61000-4-3.
EN 50147-1 / IEEE 299.
Well below the limits.
Ready for your accreditation file.
We equip the chamber for the emission and immunity standards your products must meet; site validation is done by an independent body.
Validation of the emissions test site with NSA and SVSWR.
Emissions from multimedia and IT equipment.
Emissions from industrial, scientific and medical equipment.
Radiated emissions method for the US market (FCC).
Radiated RF immunity testing.
Vehicle component tests with a dedicated setup.
We review your standards, product sizes and building.
We set the test distance, absorbers and equipment.
We install the chamber, turntable and antenna mast.
We coordinate independent CISPR 16-1-4 validation.
If your question isn't answered here, ask our engineer directly.
It is the test distance between the antenna and the product. Some standards and large products require 10 m; for small products 3 m is often enough.
Yes, once the chamber is validated to the standard. For accredited testing, the laboratory must also obtain accreditation separately.
Yes. With suitable amplifiers and antennas, immunity tests such as IEC 61000-4-3 are also performed.
It depends on chamber size and the building. We give a detailed work schedule after the survey.
NSA shows that, between 30 MHz and 1 GHz, the chamber behaves like an open-area test site. SVSWR confirms that reflections inside the chamber are low enough for measurements above 1 GHz.
It depends on the test distance and absorber type. A typical 3 m chamber is around 8–10 m long inside; 10 m chambers are far larger. We work out the exact size for your building during the survey.
Yes. For immunity testing, temporary floor absorbers are placed, suitable amplifiers and antennas are used, and field uniformity is calibrated.
Tell us about your products and the standards you test to; your survey and quote will be ready within 24 hours.
Compact chamber for desktop products.
Large equipment and full-compliance testing.
Reflection-free antenna measurement.