EMC Testing in a Semi-Anechoic Chamber

We build semi-anechoic chambers with absorber-lined walls and ceiling and a reflective floor for CE and certification testing of electronic products.

  • Design suited to CISPR 16 site validation
  • 3, 5 and 10 m test distance options
  • Turntable, antenna mast and filtered penetrations
  • SACSemi-anechoic
  • 3 / 5 / 10 mTest distance
  • CISPR 16Site validation
Get a Quote for a Semi-Anechoic ChamberA tailored quote and site survey appointment within 24 hours

or message us on WhatsApp

What is a semi-anechoic chamber?

Run Certification Tests in Your Own Facility

In a semi-anechoic chamber the walls and ceiling are covered with signal-absorbing material, while the floor is metal. This setup imitates outdoor product testing indoors.

Most of the emission and immunity tests required for CE and similar certifications are done in these chambers. They are classed as SAC-3, SAC-5 and SAC-10 by test distance.

Faster Development

No waiting in an external lab's queue.

Pass the First Time

The product is sent to testing ready.

Independent Validation

The room is tested to the standard.

Flexible Use

Emission and immunity together.

Options

Three Options for Your Needs

Let Us Help You Choose

SAC-3

3 m distance for small products.

SAC-5

5 m distance for mid-size products.

SAC-10

10 m distance for large equipment.

Technical specifications

Typical Technical Values

Values are defined per project. We give the exact figures in writing in the quote after the site survey.

Test distance3 m, 5 m or 10 m
Frequency range30 MHz – 18 GHz (depending on absorber selection)
Site validationCISPR 16-1-4 (NSA, SVSWR)
EquipmentTurntable, antenna mast, filter
StandardsCISPR 32, EN 55032, IEC 61000-4-3
Site validation

How Is a Semi-Anechoic Chamber Validated?

A semi-anechoic chamber exists to reproduce the results of an open-area test site indoors. Whether it actually does is proven by site validation measurements to CISPR 16-1-4; until they're done, the chamber can't be accepted as a test site.

Between 30 MHz and 1 GHz, normalized site attenuation (NSA) is measured and must stay within ±4 dB of the theoretical value. Above 1 GHz the SVSWR method is used, and the result must not exceed 6 dB. For immunity testing, field uniformity is calibrated to IEC 61000-4-3. These measurements are carried out by an independent accredited body, and we hand over the chamber with its reports.

  • NSA measurement

    30 MHz – 1 GHz, ±4 dB tolerance.

  • SVSWR measurement

    1–18 GHz, 6 dB limit.

  • Field uniformity

    16-point grid to IEC 61000-4-3.

  • Shielding test

    EN 50147-1 / IEEE 299.

  • Ambient noise

    Well below the limits.

  • Validation report

    Ready for your accreditation file.

Standards

The Tests You Can Run

We equip the chamber for the emission and immunity standards your products must meet; site validation is done by an independent body.

  • CISPR 16-1-4

    Validation of the emissions test site with NSA and SVSWR.

  • CISPR 32 / EN 55032

    Emissions from multimedia and IT equipment.

  • CISPR 11 / EN 55011

    Emissions from industrial, scientific and medical equipment.

  • ANSI C63.4

    Radiated emissions method for the US market (FCC).

  • IEC 61000-4-3

    Radiated RF immunity testing.

  • CISPR 25

    Vehicle component tests with a dedicated setup.

Process

From First Meeting to Handover

  1. 1

    Test Program and Survey

    We review your standards, product sizes and building.

  2. 2

    Chamber and Absorber Design

    We set the test distance, absorbers and equipment.

  3. 3

    Installation and Equipment

    We install the chamber, turntable and antenna mast.

  4. 4

    NSA and SVSWR Validation

    We coordinate independent CISPR 16-1-4 validation.

Frequently asked questions

Frequently Asked Questions About Semi-Anechoic Chambers

If your question isn't answered here, ask our engineer directly.

PhoneWhatsApp

What is the difference between SAC-3 and SAC-10?

It is the test distance between the antenna and the product. Some standards and large products require 10 m; for small products 3 m is often enough.

Is the chamber sufficient for certification testing?

Yes, once the chamber is validated to the standard. For accredited testing, the laboratory must also obtain accreditation separately.

Are immunity tests also performed?

Yes. With suitable amplifiers and antennas, immunity tests such as IEC 61000-4-3 are also performed.

How long does installation take?

It depends on chamber size and the building. We give a detailed work schedule after the survey.

What are NSA and SVSWR?

NSA shows that, between 30 MHz and 1 GHz, the chamber behaves like an open-area test site. SVSWR confirms that reflections inside the chamber are low enough for measurements above 1 GHz.

How much space does a semi-anechoic chamber need?

It depends on the test distance and absorber type. A typical 3 m chamber is around 8–10 m long inside; 10 m chambers are far larger. We work out the exact size for your building during the survey.

Can emissions and immunity tests be run in the same chamber?

Yes. For immunity testing, temporary floor absorbers are placed, suitable amplifiers and antennas are used, and field uniformity is calibrated.

Semi-anechoic chamber

Free Site Survey for Your Semi-Anechoic Chamber

Tell us about your products and the standards you test to; your survey and quote will be ready within 24 hours.

Related Solutions

All Solutions

Get a Quote

Step 1 / 2 · Your Project

What kind of room do you need?
Approximate size