Shielded Room Solutions for Data Centers

We build shielded rooms that protect your critical servers against eavesdropping, outside signals and electromagnetic pulses.

  • Cuts off signal leakage from servers
  • Protection against electromagnetic pulses (EMP)
  • Designed together with cooling and power infrastructure
  • No Signal LeakageData stays inside
  • EMP ProtectionPulse resistant
  • Cooling CompatibleFiltered air vents
Get a Quote for Data CentersA tailored quote and site survey appointment within 24 hours

or message us on WhatsApp

Why is it needed?

Data Must Also Be Protected Physically.

Cyber security is mostly provided by software. But the electromagnetic signals servers emit can be picked up from outside the building with suitable equipment.

A shielded data room cuts off this leakage and protects systems against strong outside signals. Government and defense data centers also require protection against electromagnetic pulses.

We design the room together with cooling, power and cable management; shielding doesn't make your operations harder.

Critical Server Room

Shielding of classified data servers.

EMP Protection

Pulse-resistant room construction.

Government Data Centers

Protection of classified information.

Cooling Integration

Efficient cooling with filtered penetrations.

Solutions

Rooms Used in Data Centers

Standards

Which Standards Do We Build To?

The room is designed to the standard your product or facility must meet; at handover, an independent accredited body tests it against that standard.

  • Your testing and usage needs are defined during the site survey
  • Acceptance testing by an independent body
  • Annual maintenance and re-testing are available
  • EN 50147-1 / IEEE 299

    Measuring the shielding effectiveness of data rooms.

  • MIL-STD-188-125-1

    HEMP protection for critical facilities.

  • IEC 61000-5-x

    HEMP protection methods for civil systems.

  • EN 50600

    Data center facilities and infrastructure.

  • ISO/IEC 27001

    Information security management; physical security controls.

The physical layer

The Physical Risk Software Can't Cover

Data center security is usually thought of in terms of firewalls, encryption and access control. But some risks sit at the physical layer: information extracted from signals emitted by servers and cables, powerful electromagnetic pulses damaging hardware, or interference from nearby sources.

A shielded data center reduces these risks through the structure itself. Critical server rooms are shielded, power and data lines enter through filtered and fiber penetrations, and EMP / HEMP protection can be added where needed. We plan cooling and cable routes together with the shielding design, so security doesn't come at the cost of efficiency.

  • Critical server room

    Shielded, isolated data space.

  • Signal leakage

    Emissions can't be exploited.

  • EMP / HEMP

    Pulse-protected infrastructure.

  • Cooling

    High airflow through honeycomb filters.

  • Cable penetrations

    Fiber and filtered entries.

  • Independent acceptance

    With a shielding report.

Process

From First Meeting to Handover

  1. 1

    Risk and Infrastructure Review

    We review the systems to protect, cooling and cabling.

  2. 2

    Integrated Design

    We plan shielding alongside cooling and cable routes.

  3. 3

    Non-Disruptive Installation

    We install without affecting live systems.

  4. 4

    Acceptance and Handover

    We coordinate independent acceptance testing and hand over the report.

Frequently asked questions

Frequently Asked Questions About Data Centers

If your question isn't answered here, ask our engineer directly.

PhoneWhatsApp

Does a shielded room make cooling harder?

No. Air passes through honeycomb filters that block signals; cooling capacity is planned accordingly from the start.

Can shielding be added to an existing data center later?

It is partly possible, but the best results come with a new build or during renovation. We assess the situation during the survey.

How do cables enter the room?

Data lines enter over fiber optics and power lines through filters; the shielding stays intact.

Does every data center need EMP protection?

No. It is usually required in government, defense and critical infrastructure facilities. The need is determined during the survey.

Where should the shielded room sit in the building?

Ideally away from the outer facade and strong sources such as elevators and transformers, and close to cable and cooling routes. We pick the best spot with you during the survey, backed by measurements.

Should we shield the whole data center or just the critical room?

In most cases, shielding the room or hall that houses the most critical systems is enough and more economical. We define the scope with you through a risk assessment.

How does shielding relate to EN 50600?

EN 50600 covers data center facilities and infrastructure. Shielding is designed as an additional measure within the physical security layer of that infrastructure.

Data Centers

Free Site Survey for Your Data Center Project

Tell us about your data center and the systems you want to protect; your survey and quote will be ready within 24 hours.

Get a Quote