Shielded Data Center
Shielded room that protects servers against signal leakage.
We build shielded rooms that protect your critical servers against eavesdropping, outside signals and electromagnetic pulses.
Cyber security is mostly provided by software. But the electromagnetic signals servers emit can be picked up from outside the building with suitable equipment.
A shielded data room cuts off this leakage and protects systems against strong outside signals. Government and defense data centers also require protection against electromagnetic pulses.
We design the room together with cooling, power and cable management; shielding doesn't make your operations harder.
Shielding of classified data servers.
Pulse-resistant room construction.
Protection of classified information.
Efficient cooling with filtered penetrations.
Shielded room that protects servers against signal leakage.
Room that protects critical systems against electromagnetic pulses.
The room is designed to the standard your product or facility must meet; at handover, an independent accredited body tests it against that standard.
Measuring the shielding effectiveness of data rooms.
HEMP protection for critical facilities.
HEMP protection methods for civil systems.
Data center facilities and infrastructure.
Information security management; physical security controls.
Data center security is usually thought of in terms of firewalls, encryption and access control. But some risks sit at the physical layer: information extracted from signals emitted by servers and cables, powerful electromagnetic pulses damaging hardware, or interference from nearby sources.
A shielded data center reduces these risks through the structure itself. Critical server rooms are shielded, power and data lines enter through filtered and fiber penetrations, and EMP / HEMP protection can be added where needed. We plan cooling and cable routes together with the shielding design, so security doesn't come at the cost of efficiency.
Shielded, isolated data space.
Emissions can't be exploited.
Pulse-protected infrastructure.
High airflow through honeycomb filters.
Fiber and filtered entries.
With a shielding report.
We review the systems to protect, cooling and cabling.
We plan shielding alongside cooling and cable routes.
We install without affecting live systems.
We coordinate independent acceptance testing and hand over the report.
If your question isn't answered here, ask our engineer directly.
No. Air passes through honeycomb filters that block signals; cooling capacity is planned accordingly from the start.
It is partly possible, but the best results come with a new build or during renovation. We assess the situation during the survey.
Data lines enter over fiber optics and power lines through filters; the shielding stays intact.
No. It is usually required in government, defense and critical infrastructure facilities. The need is determined during the survey.
Ideally away from the outer facade and strong sources such as elevators and transformers, and close to cable and cooling routes. We pick the best spot with you during the survey, backed by measurements.
In most cases, shielding the room or hall that houses the most critical systems is enough and more economical. We define the scope with you through a risk assessment.
EN 50600 covers data center facilities and infrastructure. Shielding is designed as an additional measure within the physical security layer of that infrastructure.
Tell us about your data center and the systems you want to protect; your survey and quote will be ready within 24 hours.