High Voltage Laboratory
Shielded laboratory for interference-free measurement in high-voltage testing.
We build shielded and magnetically shielded structures for high-voltage laboratories, control rooms and sensitive measurement areas.
Energy facilities have strong electric and magnetic fields. These fields can adversely affect nearby measuring instruments, control systems and computers.
High-voltage laboratories measure very weak signals such as partial discharge; outside interference can make these measurements impossible. A shielded laboratory solves this.
In offices and control rooms near substations, magnetic shielding prevents screen flicker and equipment faults.
Laboratory for cable and transformer testing.
Reducing fields from transformers.
Protection of critical control systems.
Inverter and power electronics testing.
Shielded laboratory for interference-free measurement in high-voltage testing.
Special cladding that reduces magnetic fields from transformers and cables.
The room is designed to the standard your product or facility must meet; at handover, an independent accredited body tests it against that standard.
High-voltage test techniques and measurement methods.
Partial discharge measurements.
Generic EMC emission and immunity for industrial environments.
Directive on worker exposure to electromagnetic fields.
Shielding effectiveness of labs and rooms.
In the energy sector, shielding serves two different purposes. The first is test laboratories: partial discharge measurements on transformers, cables and switchgear look for signals in the picocoulomb range, and outside noise easily corrupts them. The second is offices and control rooms next to substations and busbar trunking.
The 50 Hz magnetic field from transformers can cause flickering screens, disturbed measurements and an uncomfortable environment for staff. That field isn't reduced by RF shielding but by high-permeability materials such as steel or mu-metal. We measure the field first, design a solution that fits, and document the improvement by measuring again.
Low noise in a shielded lab.
Near transformers and busbars.
The first sign of a magnetic field.
High-permeability materials.
Testing inverters and plant equipment.
Improvement documented in numbers.
We measure the magnetic field or lab noise.
We choose the shielding material and structure.
We build the shielded lab or magnetic shield.
We report before-and-after values side by side.
If your question isn't answered here, ask our engineer directly.
Normal shielding blocks radio signals. The low-frequency magnetic fields of transformers and cables require special magnetic materials.
Yes. During the survey we measure the field level and identify the source of the problem and the right shielding method.
The test voltage and the size of the equipment to be tested determine the required safety clearances and room size.
Yes. Measurements before and after are delivered side by side in a report.
The 50 Hz magnetic field from transformers and busbars can make monitors flicker and distort. We measure the field to identify its source and strength, then reduce it with suitable magnetic shielding.
Inverters and power electronics require emission and immunity testing. Depending on the equipment size, we recommend a shielded room or a semi-anechoic chamber.
Yes. Magnetic shielding panels applied to walls, floors or ceilings can reduce the field in existing offices and control rooms.
Tell us briefly about your facility and the problem you're facing; your survey and quote will be ready within 24 hours.