Cyber Security Rooms for Police and Public Security

From the moment they enter the room, seized phones and computers can't connect to the outside world; evidence can't be wiped and the device can't be located.

  • Mobile network, Wi-Fi, Bluetooth and GPS signals can't get in
  • Continuous protection from field to lab: from evidence box to room
  • Turnkey installation in your building or in a container
  • Signal IsolationThe device cannot connect
  • Evidence SecurityCan't be wiped remotely
  • 4 Different TypesFrom enclosure to container
Get a Quote for Police and Public SecurityA tailored quote and site survey appointment within 24 hours

or message us on WhatsApp

Why is it needed?

Evidence Must Be Preserved as It Was Seized.

If a suspect's phone connects to a network even once after seizure, it can be wiped or locked remotely, or its location reported to the other side. That means losing evidence to be used in court.

A cyber security room is a signal-proof workspace where the examination team can examine devices switched on and running, comfortably for hours. Power, internet and air conditioning are provided through special parts that don't break the isolation.

Forensic evidence boxes for the time between the scene and the laboratory, and portable shielded containers for units away from headquarters, provide the same protection.

Mobile Device Examination

Data extraction from phones and tablets is done under signal isolation.

Evidence Preservation

Devices awaiting examination are stored in a disconnected environment.

Field and Regional Units

The same security outside headquarters with a shielded container.

Training and Exercises

Training teams with real devices in a secure environment.

Solutions

Rooms Used in Police and Public Security

Standards

Which Standards Do We Build To?

The room is designed to the standard your product or facility must meet; at handover, an independent accredited body tests it against that standard.

  • Your testing and usage needs are defined during the site survey
  • Acceptance testing by an independent body
  • Annual maintenance and re-testing are available
  • EN 50147-1

    Shielding effectiveness of shielded rooms and cabinets.

  • IEEE 299

    International test standard for shielded enclosures.

  • IEEE 299.1

    Test method for small shielded cabinets and boxes.

  • ISO/IEC 17025

    General requirements for the competence of forensic labs.

  • ISO/IEC 27037

    Guidelines for collecting and preserving digital evidence.

From HQ to the field

One Chain of Protection From HQ to the Field

In public safety agencies, digital evidence has to be protected not only in the central lab but at the scene, in regional units and in transit. A strong central lab isn't enough on its own if the evidence isn't protected on its way there.

That's why we plan cyber security rooms for the central lab, shielded cabinets for regional units, and shielded containers and evidence boxes for field operations, all at the same level of protection. We also support technical specification work for public tenders, so what you procure is delivered with measurable performance.

  • Central lab

    Multi-station cyber security room.

  • Regional units

    Compact shielded cabinets.

  • Field operations

    Shielded containers and evidence boxes.

  • Training areas

    Shielded space for drills and training.

  • Specification support

    Measurable technical specifications.

  • Independent acceptance test

    Every unit independently tested.

Process

From First Meeting to Handover

  1. 1

    Needs and Unit Review

    We define needs across central, regional and field units.

  2. 2

    Specification and Plan

    We prepare measurable specifications and a rollout plan.

  3. 3

    Installation and Delivery

    We build rooms and deliver cabinets and containers.

  4. 4

    Acceptance and Training

    We coordinate independent testing and train the users.

Frequently asked questions

Frequently Asked Questions About Police and Public Security

If your question isn't answered here, ask our engineer directly.

PhoneWhatsApp

How many examination stations is the room designed for?

It is designed to need, from a single-person shielded enclosure to multi-station laboratories. We decide together during the survey how many specialists will work at once.

Can the internet be used inside?

Yes. The organization's network enters the room over fiber optic cable through special penetrations that create no signal leakage.

Do signals get in when the door opens?

Isolation is lost while the door is open. That's why for heavy use we recommend a shielded double-door entry vestibule; one door doesn't open until the other closes.

Do you provide technical specification support for public tenders?

Yes. We help you prepare a draft technical specification and measurement criteria suited to your needs.

What suits regional units?

Units with lower examination volumes are usually well served by compact shielded cabinets and evidence boxes. Busier units benefit from a small cyber security room.

What do you recommend for field operations?

Evidence boxes and shielded bags at the scene, and shielded containers with examination space for longer field deployments.

Do you train users?

Yes. At handover we train users on closing the door properly, using the penetrations and running the room's daily checks.

Law Enforcement and Public Safety

Free Site Survey for Your Police and Public Security Project

Tell us about your units and examination capacity; your survey and quote will be ready within 24 hours.

Get a Quote

Step 1 / 2 · Your Project

What kind of room do you need?
Approximate size