Acceptance Testing
Handover testing of a new room.
We measure and report how well your shielded room blocks signals using EN 50147-1, IEEE 299 or MIL-STD-285 methods.
A shielded room's performance can only be known by measuring it. Worn gaskets, cables added later or faulty installation lower performance without anyone noticing.
We measure at different frequencies with antennas placed inside and outside the room, check critical points such as the door and penetrations one by one, and deliver the result in a signed report.
Measured with an international method.
The leak is located.
A document for audits and tenders.
The fix is planned.
Handover testing of a new room.
Annual performance check and reporting.
Locating the leak point.
Values are defined per project. We give the exact figures in writing in the quote after the site survey.
Industries where it is used
| Methods | EN 50147-1, IEEE 299, MIL-STD-285 |
|---|---|
| Frequency range | From magnetic fields up to GHz |
| Measurement points | Door, filters, penetrations, joints |
| Output | Signed test report |
| Room types | All brands and types |
The test is done twice with the same transmitter and receiver. First, a reference level is measured with no room between them; then the transmitter goes outside the room and the receiver inside, and the measurement is repeated. The difference between the two gives the room's shielding at that frequency, in decibels.
Loop antennas are used for magnetic fields at low frequencies, and dipole and horn antennas at higher frequencies. Weak points such as the door, filters, ventilation and panel joints are scanned separately, and any leak is pinpointed. You get a signed report with results by frequency, photos and recommended fixes.
Signal level without the room.
Transmitter outside, receiver inside.
Loop antenna at low frequencies.
Dipole and horn antennas.
Doors, filters and joints.
Results, photos and recommendations.
We test to the method your room's specification or tender documents call for.
The most widely used method for shielded rooms in Europe.
International method for shielded enclosures larger than 2 m.
Method for shielded cabinets and boxes smaller than 2 m.
Test method cited in older military specifications.
Specification for high-security shielded enclosures.
We define the room, specification and test points.
We measure the reference signal level outside the room.
We measure shielding at the agreed frequencies and points.
We hand over a signed report with recommended fixes.
If your question isn't answered here, ask our engineer directly.
The method specified in the contract or specification is used. If none is specified, EN 50147-1 or IEEE 299 is recommended.
Yes. We test and report regardless of brand or type.
Depending on room size and the number of measurement points, it is usually completed within one working day.
We report the leak point and offer a solution and quote for repair or renewal.
Not completely. Access to the test points, especially around doors and penetrations, is enough. The room shouldn't be in use during the test.
They're set by the room's purpose and specification. Testing usually covers several selected frequencies, from low-frequency magnetic fields up to the GHz range.
Yes. The report covers the method, equipment, test points and results by frequency, and can go into acceptance, audit or tender files.
Tell us the room type and the test method required; your survey and quote will be ready within 24 hours.
Keep your room performing as on day one.
Shielded cage for R&D and testing.
Interference-free room for sensitive measurements.