Shielding Effectiveness Testing

We measure and report how well your shielded room blocks signals using EN 50147-1, IEEE 299 or MIL-STD-285 methods.

  • Point-by-point measurement at doors, filters and penetrations
  • Signed report following the standard method
  • Recommended fixes for problem points
  • EN 50147-1Test method
  • ReportedSigned result
  • DiagnosisWeak point detection
Get a Quote for Shielding TestingA tailored quote and site survey appointment within 24 hours

or message us on WhatsApp

What is shielding testing?

Does Your Room Really Work?

A shielded room's performance can only be known by measuring it. Worn gaskets, cables added later or faulty installation lower performance without anyone noticing.

We measure at different frequencies with antennas placed inside and outside the room, check critical points such as the door and penetrations one by one, and deliver the result in a signed report.

Standard Method

Measured with an international method.

Weak Point

The leak is located.

Signed Report

A document for audits and tenders.

Recommended Fix

The fix is planned.

Options

Three Options for Your Needs

Let Us Help You Choose

Acceptance Testing

Handover testing of a new room.

Periodic Testing

Annual performance check and reporting.

Fault Finding

Locating the leak point.

Technical specifications

Typical Technical Values

Values are defined per project. We give the exact figures in writing in the quote after the site survey.

MethodsEN 50147-1, IEEE 299, MIL-STD-285
Frequency rangeFrom magnetic fields up to GHz
Measurement pointsDoor, filters, penetrations, joints
OutputSigned test report
Room typesAll brands and types
How testing works

Shielding Testing, Step by Step

The test is done twice with the same transmitter and receiver. First, a reference level is measured with no room between them; then the transmitter goes outside the room and the receiver inside, and the measurement is repeated. The difference between the two gives the room's shielding at that frequency, in decibels.

Loop antennas are used for magnetic fields at low frequencies, and dipole and horn antennas at higher frequencies. Weak points such as the door, filters, ventilation and panel joints are scanned separately, and any leak is pinpointed. You get a signed report with results by frequency, photos and recommended fixes.

  • Reference measurement

    Signal level without the room.

  • Measurement through the room

    Transmitter outside, receiver inside.

  • Magnetic field

    Loop antenna at low frequencies.

  • High frequencies

    Dipole and horn antennas.

  • Leak scan

    Doors, filters and joints.

  • Signed report

    Results, photos and recommendations.

Standards

Which Method Do We Use?

We test to the method your room's specification or tender documents call for.

  • EN 50147-1

    The most widely used method for shielded rooms in Europe.

  • IEEE 299

    International method for shielded enclosures larger than 2 m.

  • IEEE 299.1

    Method for shielded cabinets and boxes smaller than 2 m.

  • MIL-STD-285

    Test method cited in older military specifications.

  • NSA 94-106

    Specification for high-security shielded enclosures.

Process

From First Meeting to Handover

  1. 1

    Scope and Method

    We define the room, specification and test points.

  2. 2

    Reference Measurement

    We measure the reference signal level outside the room.

  3. 3

    Room Measurement

    We measure shielding at the agreed frequencies and points.

  4. 4

    Report and Recommendations

    We hand over a signed report with recommended fixes.

Frequently asked questions

Frequently Asked Questions About Shielding Testing

If your question isn't answered here, ask our engineer directly.

PhoneWhatsApp

Which method should be used?

The method specified in the contract or specification is used. If none is specified, EN 50147-1 or IEEE 299 is recommended.

Can you test a room built by another company?

Yes. We test and report regardless of brand or type.

How long does testing take?

Depending on room size and the number of measurement points, it is usually completed within one working day.

What happens if the result is poor?

We report the leak point and offer a solution and quote for repair or renewal.

Does the room need to be emptied for testing?

Not completely. Access to the test points, especially around doors and penetrations, is enough. The room shouldn't be in use during the test.

Which frequencies are tested?

They're set by the room's purpose and specification. Testing usually covers several selected frequencies, from low-frequency magnetic fields up to the GHz range.

Can the report be used for tenders and audits?

Yes. The report covers the method, equipment, test points and results by frequency, and can go into acceptance, audit or tender files.

Shielding testing

Free Site Survey for Shielding Testing

Tell us the room type and the test method required; your survey and quote will be ready within 24 hours.