TEMPEST Enclosure
Enclosure for a single workstation.
We build TEMPEST rooms that stop information leaking through signals emitted by computers, displays and cables, at the room level.
Every electronic device emits weak signals while running. With suitable equipment, the image on a screen or the text being typed can be reconstructed from outside using these signals.
A TEMPEST room cuts off this leakage at the room level. All devices inside are protected together; every line entering the room is filtered so it can't carry information.
Emissions can't be picked up from outside.
No information leaks through the lines.
Conversations are held securely.
Access is logged.
Enclosure for a single workstation.
Shielded and acoustically insulated room.
Multi-room, integrated secure facility.
Values are defined per project. We give the exact figures in writing in the quote after the site survey.
Industries where it is used
| Design basis | NATO SDIP-27 / SDIP-29 |
|---|---|
| Signal attenuation | 100 dB and above |
| Line protection | Power, data, telephone and air filters |
| Option | Acoustic insulation, access control |
| Independent acceptance test | EN 50147-1 and project specification |
Computers, displays and cables give off unintended signals related to the information they process. Someone with the right equipment can pick up these signals from a distance and reconstruct that information. A TEMPEST room stops this leakage from leaving your facility.
But the room alone isn't enough. Zoning of the area, separation of classified and unclassified lines, filtering of every conductive line and fiber data links all have to be planned together. We design the room as part of that whole, in line with the requirements set by the competent authorities, and its performance is documented by independent testing.
The area's protection against the outside is measured.
Classified and unclassified lines are kept apart.
Power and signal lines carry no leakage.
No copper cables breaching the shield.
Conversations can't be overheard.
Performance is verified regularly.
Detailed requirements are set out in restricted documents shared through the competent authorities. We design to those requirements.
NATO classification of equipment into levels A, B and C by emission level.
Zoning of facility areas and zone assessment.
Installation and cabling rules for facilities processing classified information.
Measuring and reporting the room's shielding effectiveness.
Acceptance criteria set by your national security authority.
We assess security requirements and the zone of the area.
We plan shielding, line separation, filters and acoustics together.
Authorized staff install the room under strict confidentiality.
We coordinate independent acceptance testing.
If your question isn't answered here, ask our engineer directly.
It is required for government bodies processing classified information, defense companies, embassies and critical infrastructure operators.
In addition to shielding, all lines are filtered so they leak no information, and zones are separated.
Yes. The shielding stays inside the walls; the interior surface is finished to match your office design.
If requested, the room is also acoustically insulated so conversations can't be heard from outside.
If the room's protection is sufficient and accepted by the competent authorities, commercial equipment can be used inside. That's often more economical than buying certified equipment.
A cyber security room stops seized devices from communicating with the outside world. A TEMPEST room stops classified information processed inside from leaking out through the signals equipment emits.
In most cases, yes. A modular shielded structure is built inside the existing room and the interior is finished to look like an office. We assess the space during the survey.
Share the area to be protected and how it will be used, within your confidentiality rules; your survey and quote will be ready within 24 hours.
Room that isolates evidence devices from signals.
Interference-free room for sensitive measurements.
Protects critical systems against pulses.