Shielded and Anechoic Room Relocation

We dismantle your existing shielded room, anechoic chamber or antenna chamber, move it to its new site and reinstall it.

  • Dismantling, packing and transport from a single source
  • Installation and services at the new site
  • Independent post-installation acceptance
  • Single sourceDismantling and transport
  • InstallationAt the new site
  • TestedDelivered with a report
Get a Quote for Room RelocationA tailored quote and site survey appointment within 24 hours

or message us on WhatsApp

What is room relocation?

No Performance Lost in the Move

Shielded rooms are modular, but gaskets, joints and penetrations can be damaged in a move. A badly done relocation permanently lowers the room's performance.

We first measure the room, dismantle it with numbered parts, transport it safely and install it at the new site. Worn gaskets are renewed and acceptance testing is carried out by an independent body.

Initial Measurement

The condition before the move is recorded.

Safe Transport

Parts are numbered and packed.

Renewal

Worn gaskets are replaced.

Final Measurement

Independently tested at the new site.

Options

Three Options for Your Needs

Let Us Help You Choose

In-Building Relocation

Relocation within the same building.

Local / Intercity Relocation

Dismantling, shipping and installation at a new facility.

International Relocation

Customs and logistics included.

Technical specifications

Typical Technical Values

Values are defined per project. We give the exact figures in writing in the quote after the site survey.

ScopeDismantling, packing, transport, installation
Room typesShielded, anechoic, cyber, TEMPEST
RenewalGasket, filter and lock replacement
TestingBefore and after the move
RegionWorldwide
Relocation risks

The Mistakes That Cost Performance in a Move

Shielded and anechoic rooms can be dismantled and rebuilt, but if it's done wrong, the room won't perform as it did at its new site. The problems we see most are panels removed without numbering, damaged mating surfaces, reused worn gaskets, broken absorbers and uneven floors in the new building.

Before the move, we measure the room and record its current performance. We number every part, pack it in protective packaging and check the new building before installation. During reassembly we replace worn gaskets and filters; an independent accredited body then carries out acceptance testing, so before-and-after performance can be compared on paper.

  • Pre-move test

    Current performance on record.

  • Numbering

    Every panel goes back in place.

  • Protective packing

    Mating surfaces and absorbers protected.

  • Building check

    Floor and dimensions verified in advance.

  • Gasket and filter renewal

    Worn parts replaced.

  • Independent acceptance

    Independently tested and compared.

Standards

Pre- and Post-Move Test Standards

We run the pre-move check to the standard that fits the room type; post-move acceptance testing is done by an independent body and compared with it.

  • EN 50147-1 / IEEE 299

    Shielding effectiveness of shielded rooms.

  • CISPR 16-1-4

    NSA and SVSWR validation of anechoic EMC chambers.

  • IEEE 149

    System validation of antenna measurement chambers.

  • NSA 94-106

    Test specification for high-security shielded rooms.

  • ISO/IEC 17025

    Re-validation records for accredited laboratories after a move.

What we move

Chambers We Relocate

Every chamber type has its own critical points in a move. We build the plan around your chamber and the conditions at the new site.

Semi-Anechoic EMC Chamber

SAC-3, SAC-5 and SAC-10 chambers

NSA · SVSWRre-validation
  • Ferrite and hybrid absorber removal
  • Flush turntable and ground plane
  • Field uniformity calibration
Get a Quote

Fully Anechoic Chamber

OTA and broadband measurement rooms

Floor includedabsorber lining
  • Floor absorbers removed and stored
  • Positioner relocation
  • Quiet-zone check
Get a Quote
Precision Move

Antenna Measurement Chamber

Far-field, near-field and compact range

Alignmentre-calibration
  • Reflector and scanner protection
  • Positioner alignment
  • Quiet-zone verification
Get a Quote

CISPR 25 / MIL-STD Chamber

Chambers with ground-plane test benches

Test benchbonding continuity
  • Ground-plane bonding
  • Filtered power entries
  • LISN and bench layout
Get a Quote
Antenna chamber relocation

Moving an Antenna Chamber Takes Millimeter Precision

An antenna measurement range is only as good as its alignment. The compact-range reflector, near-field scanner and positioner all have to return to the same geometry at the new site; otherwise the patterns you measure will no longer match your reference data.

We crate reflectors so nothing ever touches the surface and remove phase-stable RF cables without exceeding their bend radius. At the new site we re-level and re-align positioners and scanners, then check the quiet zone and the full measurement chain with a standard gain horn before the range goes back into service.

  • Compact-range reflector

    Crated so the surface is never touched.

  • Near-field scanner

    Planarity re-set at the new site.

  • Positioner

    Axes re-aligned, reference points re-taken.

  • Phase-stable cables

    Removed and shipped within their bend radius.

  • Quiet zone

    Reflectivity measured again.

  • Reference antenna check

    System verified with a standard gain horn.

Process

From First Meeting to Handover

  1. 1

    Pre-Move Test and Survey

    We test the room and survey both sites.

  2. 2

    Dismantling and Packing

    We number every part and pack it securely.

  3. 3

    Transport and Installation

    We move the room and rebuild it at the new site.

  4. 4

    Independent Acceptance

    We coordinate independent acceptance testing and compare the results.

Frequently asked questions

Frequently Asked Questions About Room Relocation

If your question isn't answered here, ask our engineer directly.

PhoneWhatsApp

Can a room installed by another company be relocated?

Yes. During the survey we examine the room's construction and determine whether it can be moved and what renewal is needed.

Does performance drop after relocation?

With correct dismantling and gasket renewal the room returns to its original performance; independent acceptance testing proves it.

Can the room be enlarged or reduced?

Thanks to the modular construction, a size change can be planned during relocation.

How long does it take?

It depends on room size and distance; we give a work schedule after the survey.

What should be prepared at the new building?

Floor flatness and load capacity, ceiling height, entrance dimensions, and power and HVAC provisions should all be checked in advance. We give you a building preparation checklist.

Do you handle international relocations?

Yes. We relocate rooms worldwide, handling packing, logistics planning, installation and testing in the new country as a single service.

Can the room be upgraded during the move?

Yes. A move is a good opportunity to renew gaskets, filters and locks, add penetrations or enlarge the room; this work can be done during reinstallation.

Can the absorbers be reused?

Sound absorbers are reused. Because some ferrite tiles crack during removal and older foam absorbers deteriorate over time, we identify which ones need replacing during the survey.

Does the chamber need to be re-validated after the move?

Yes. A move changes the chamber's geometry and ground-plane bonding. The chamber shouldn't be used as a test site until NSA, SVSWR and shielding measurements have been repeated. These validation measurements are carried out by an independent accredited body.

Room relocation

Free Site Survey for Room Relocation

Tell us the room type and its current and new locations; your survey and quote will be ready within 24 hours.

Related Solutions

All Solutions

Get a Quote

Step 1 / 2 · Your Project

What kind of room do you need?
Approximate size