Antenna Measurement Chambers for Telecom and 5G

Measure the performance of antennas, phones and wireless devices without reflections, with repeatable results.

  • Anechoic chamber for antenna and wireless device measurement
  • Absorber selection suited to 5G and high-frequency testing
  • Designed around your test equipment, with independent acceptance testing
  • Anechoic EnvironmentReflection-free measurement
  • 5G ReadyHigh frequency
  • Antenna TestingGain and pattern
Get a Quote for Telecom and 5GA tailored quote and site survey appointment within 24 hours

or message us on WhatsApp

Why is it needed?

Accurate Measurement Happens Without Reflections.

When measuring the wireless performance of an antenna or phone, signals reflected from the walls spoil the result. Outside base station and Wi-Fi signals also mix into the measurement.

An anechoic chamber solves two problems at once: shielding blocks outside signals, and absorber material covering the inner surfaces eliminates reflections.

With 5G, frequencies rose and measurement sensitivity increased. We choose absorber material and chamber size according to the frequencies you'll test.

Antenna Design

Antenna gain and pattern measurement.

Device Performance

Phone and modem testing.

Base Station

Base station antenna testing.

Wi-Fi and IoT

Wireless module and smart device testing.

Solutions

Rooms Used in Telecom and 5G

Fully Anechoic Chamber

Reflection-free measurement chamber with absorbers on all surfaces, including the floor.

Standards

Which Standards Do We Build To?

The room is designed to the standard your product or facility must meet; at handover, an independent accredited body tests it against that standard.

  • Your testing and usage needs are defined during the site survey
  • Acceptance testing by an independent body
  • Annual maintenance and re-testing are available
  • 3GPP TS 38.521-2

    OTA conformance testing of 5G FR2 devices.

  • 3GPP TS 38.141-2

    Radiated conformance testing of 5G base stations.

  • CTIA OTA

    Test plan for TRP and TIS of cellular and Wi-Fi devices.

  • IEEE 149

    Antenna measurement methods.

  • ETSI EN 301 908

    RED radio requirements for cellular devices.

The right test environment

From Box to Chamber: Which Test, Which Environment?

In telecom, not every measurement needs the same environment. An RF shield box is enough for functional and conducted tests on the production line. Over-the-air device performance, meaning TRP and TIS, needs an anechoic chamber. For antenna design, radiation pattern and gain are measured with a far-field, near-field or compact range setup.

5G mmWave raised the bar: at higher frequencies cable losses grow, antennas are built into the device, and measurements have to be made over the air. We look at your product range, frequencies and test volume and define the right mix of boxes, chambers and measurement systems with you.

  • RF shield box

    Production line and conducted tests.

  • OTA measurement

    TRP, TIS and antenna efficiency.

  • Antenna measurement

    Radiation pattern and gain.

  • 5G mmWave

    FR2 measurement with a compact range.

  • Base stations

    Near-field for large antennas.

  • Wi-Fi and IoT

    2.4 / 5 / 6 GHz testing.

Process

From First Meeting to Handover

  1. 1

    Product and Frequency Review

    We review your devices, frequencies and test needs.

  2. 2

    Test Environment Selection

    We define boxes, chambers and methods with you.

  3. 3

    Installation and Integration

    We install the chamber, positioner and system.

  4. 4

    Quiet-Zone Validation

    We coordinate independent quiet-zone validation.

Frequently asked questions

Frequently Asked Questions About Telecom and 5G

If your question isn't answered here, ask our engineer directly.

PhoneWhatsApp

What is the difference between a fully anechoic and a semi-anechoic chamber?

In a fully anechoic chamber all surfaces, including the floor, are covered with absorbers; it is ideal for antenna measurements. In a semi-anechoic chamber the floor is reflective; it is used for EMC testing.

What determines the chamber size?

The lowest frequency to be measured and the device size determine the chamber size. Compact chambers may be enough for small antennas.

Do you also install the measurement system?

We prepare the chamber to suit your measurement system, together with the antenna mast, turntable and cable penetrations.

Can the chamber be adapted to new frequencies?

The chamber's operating range can be extended by changing or adding absorber material.

When is an RF shield box enough?

It's usually enough for functional tests and conducted measurements on the production line. Antenna performance and over-the-air measurements need an anechoic chamber.

What is a reverberation chamber for?

A reverberation chamber deliberately increases reflections to create a uniform field. It's a fast, economical alternative for measurements such as total radiated power and antenna efficiency.

How are base station antennas measured?

Large base station antennas are usually measured with near-field scanners or compact range systems, which keeps the chamber size reasonable.

Telecom and 5G

Free Site Survey for Your Telecom and 5G Project

Tell us which devices you'll measure and over what frequency range; your survey and quote will be ready within 24 hours.

Get a Quote

Step 1 / 2 · Your Project

What kind of room do you need?
Approximate size