RF / EMI Shielded Room

We build high-performance shielded rooms where you can carry out sensitive measurements and tests unaffected by outside signal noise.

  • High signal blocking at high frequencies
  • Filtered power, fiber data and air penetrations
  • Independent acceptance testing to EN 50147-1 or IEEE 299
  • ≥ 100 dBSignal attenuation
  • 40 GHzUpper frequency option
  • TestedDelivered with a report
Get a Quote for an RF / EMI Shielded RoomA tailored quote and site survey appointment within 24 hours

or message us on WhatsApp

What is an RF / EMI shielded room?

Clean Measurement Starts with a Noise-Free Environment

The biggest factor spoiling measurement results in laboratories is outside radio signals and electrical noise. An RF / EMI shielded room cuts this noise out.

The room is designed as a whole with panels, a gasketed door, honeycomb air filters and line filters, so measurements inside are repeatable and reliable.

Low Noise

Outside signals don't mix into measurements.

Repeatable

Gives the same result every day.

Filtered Services

Power and data lines don't leak.

Expandable

The room is expanded as needs grow.

Options

Three Options for Your Needs

Let Us Help You Choose

Measurement Enclosure

Compact enclosure for a single bench.

Laboratory Room

Permanent shielded room with services ready.

Multi-Room Facility

Facility with separate control and test areas.

Technical specifications

Typical Technical Values

Values are defined per project. We give the exact figures in writing in the quote after the site survey.

Signal attenuation100 dB and above (1 GHz)
Frequency range10 kHz – 18 GHz, optional 40 GHz
PenetrationsLine filter, fiber panel, honeycomb filter
DoorManual or automatic, double-row gaskets
Independent acceptance testEN 50147-1 or IEEE 299
Choosing the right level

How Much Shielding Do You Really Need?

Shielding is expressed in decibels, and every 20 dB means the signal is ten times weaker. A 60 dB room attenuates outside signals a thousandfold; a 100 dB room, a hundred-thousandfold. Too little corrupts your measurements, and too much inflates your budget for nothing.

The right level depends on how sensitive your measurements are and on the signal environment where the room will stand. That's why we measure the site during the survey and work out your requirement from the lowest frequency to the highest. Low-frequency magnetic fields call for different measures than high frequencies, so we assess them separately.

  • Blocking phones and Wi-Fi

    Typically 60–80 dB is enough.

  • Sensitive lab measurements

    Usually 80–100 dB.

  • EMC testing and security

    100 dB and above.

  • Low-frequency magnetic fields

    Steel panels and extra measures.

  • Doors and penetrations

    They set the room's real limit.

  • Site measurement

    We measure and recommend the right level.

Standards

Test and Acceptance Standards

An independent accredited body measures and reports the room's performance to the standard your specification calls for.

  • EN 50147-1

    Shielding effectiveness of shielded rooms; the most widely used method in Europe.

  • IEEE 299

    International test standard for shielded enclosures.

  • MIL-STD-285

    The predecessor of IEEE 299, still cited in older military specifications.

  • NSA 94-106

    Specification for high-performance shielded enclosures.

  • IEC 61000-4-x

    The basic standard series for immunity tests run inside the room.

Process

From First Meeting to Handover

  1. 1

    Site Measurement

    We measure the signals at your site and set the required level.

  2. 2

    Design and Penetration Plan

    We plan the room size, door, filters and fiber penetrations.

  3. 3

    Manufacture and Installation

    We build the modular room and connect services and HVAC.

  4. 4

    Independent Acceptance Test

    We coordinate independent acceptance testing and hand over the report.

Frequently asked questions

Frequently Asked Questions About RF / EMI Shielded Rooms

If your question isn't answered here, ask our engineer directly.

PhoneWhatsApp

What is the difference between a shielded room and an anechoic chamber?

A shielded room blocks outside signals. In an anechoic chamber, the inner surfaces are also covered with absorbers so reflections are eliminated too.

Can the internet be used inside the room?

Yes. Data lines enter the room over fiber optics through special penetrations that don't leak signals.

What level of shielding do I need?

It is determined by the sensitivity of the measurement. We recommend the right level after measuring the environment during the survey.

Can our existing room be converted into a shielded room?

In most cases, yes. Room dimensions, floor and door position are assessed during the survey.

Is an RF shielded room the same as an EMI shielded room?

In practice, yes. RF shielding refers to blocking radio-frequency signals and EMI shielding to blocking electromagnetic interference; both are achieved with the same shielded room construction.

Can the room have air conditioning and lighting?

Yes. Air enters through honeycomb filters and power through a filtered entry, and low-noise lighting keeps measurements clean.

Can a shielded room be moved to another building?

Yes. Thanks to its modular construction, the room can be dismantled and rebuilt at the new site. The shielding is then re-tested by an independent body and a new report is issued.

RF / EMI shielded room

Free Site Survey for Your RF / EMI Shielded Room

Tell us what you'll measure and roughly how big the room should be; your survey and quote will be ready within 24 hours.

Related Solutions

All Solutions

Get a Quote

Step 1 / 2 · Your Project

What kind of room do you need?
Approximate size