Measurement Enclosure
Compact enclosure for a single bench.
We build high-performance shielded rooms where you can carry out sensitive measurements and tests unaffected by outside signal noise.
The biggest factor spoiling measurement results in laboratories is outside radio signals and electrical noise. An RF / EMI shielded room cuts this noise out.
The room is designed as a whole with panels, a gasketed door, honeycomb air filters and line filters, so measurements inside are repeatable and reliable.
Outside signals don't mix into measurements.
Gives the same result every day.
Power and data lines don't leak.
The room is expanded as needs grow.
Compact enclosure for a single bench.
Permanent shielded room with services ready.
Facility with separate control and test areas.
Values are defined per project. We give the exact figures in writing in the quote after the site survey.
Industries where it is used
| Signal attenuation | 100 dB and above (1 GHz) |
|---|---|
| Frequency range | 10 kHz – 18 GHz, optional 40 GHz |
| Penetrations | Line filter, fiber panel, honeycomb filter |
| Door | Manual or automatic, double-row gaskets |
| Independent acceptance test | EN 50147-1 or IEEE 299 |
Shielding is expressed in decibels, and every 20 dB means the signal is ten times weaker. A 60 dB room attenuates outside signals a thousandfold; a 100 dB room, a hundred-thousandfold. Too little corrupts your measurements, and too much inflates your budget for nothing.
The right level depends on how sensitive your measurements are and on the signal environment where the room will stand. That's why we measure the site during the survey and work out your requirement from the lowest frequency to the highest. Low-frequency magnetic fields call for different measures than high frequencies, so we assess them separately.
Typically 60–80 dB is enough.
Usually 80–100 dB.
100 dB and above.
Steel panels and extra measures.
They set the room's real limit.
We measure and recommend the right level.
An independent accredited body measures and reports the room's performance to the standard your specification calls for.
Shielding effectiveness of shielded rooms; the most widely used method in Europe.
International test standard for shielded enclosures.
The predecessor of IEEE 299, still cited in older military specifications.
Specification for high-performance shielded enclosures.
The basic standard series for immunity tests run inside the room.
We measure the signals at your site and set the required level.
We plan the room size, door, filters and fiber penetrations.
We build the modular room and connect services and HVAC.
We coordinate independent acceptance testing and hand over the report.
If your question isn't answered here, ask our engineer directly.
A shielded room blocks outside signals. In an anechoic chamber, the inner surfaces are also covered with absorbers so reflections are eliminated too.
Yes. Data lines enter the room over fiber optics through special penetrations that don't leak signals.
It is determined by the sensitivity of the measurement. We recommend the right level after measuring the environment during the survey.
In most cases, yes. Room dimensions, floor and door position are assessed during the survey.
In practice, yes. RF shielding refers to blocking radio-frequency signals and EMI shielding to blocking electromagnetic interference; both are achieved with the same shielded room construction.
Yes. Air enters through honeycomb filters and power through a filtered entry, and low-noise lighting keeps measurements clean.
Yes. Thanks to its modular construction, the room can be dismantled and rebuilt at the new site. The shielding is then re-tested by an independent body and a new report is issued.
Tell us what you'll measure and roughly how big the room should be; your survey and quote will be ready within 24 hours.
Shielded cage for R&D and testing.
For CE and certification testing.
We measure performance and report it.