Compact FAR
For small antennas and IoT.
We build fully anechoic chambers with absorbers on every surface, including the floor, providing a reflection-free measurement environment.
In a fully anechoic chamber all surfaces, including the floor, are covered with absorbers. With no reflections from any surface, the device is measured as if suspended in empty space.
Antenna gain, pattern performance and the over-the-air performance of wireless devices are measured in these chambers. Absorbers are chosen for the frequencies to be measured.
Measurement is as if in free space.
Low to high frequency.
Every measurement gives the same result.
Antenna and device testing together.
For small antennas and IoT.
For antennas and wireless devices.
With reflector for large antennas.
Values are defined per project. We give the exact figures in writing in the quote after the site survey.
Industries where it is used
| Surfaces | Absorbers everywhere, including the floor |
|---|---|
| Frequency range | 400 MHz – 40 GHz (depending on absorber) |
| Measurement system | Positioner, antenna mast |
| Shielding | 100 dB and above |
| Application | Antenna, OTA, radar measurement |
In a fully anechoic chamber, every surface including the floor is covered with absorbers, so the antenna inside sees only the direct signal. The single biggest factor in how well the chamber works is the type and size of those absorbers.
Pyramidal absorbers work according to their height: the lower your lowest operating frequency, the taller the absorber and the larger the chamber. At lower frequencies, ferrite tiles or hybrid absorbers are used. Chamber quality is proven by the reflectivity measured in the quiet zone after installation. We choose absorbers with you based on your lowest frequency and budget.
Low reflectivity at high frequencies.
Compact solution at low frequencies.
Chosen for the lowest frequency.
Reflection-free area for the device.
Performance verified after installation.
Outside signals stay out of the measurement.
We design the chamber to match your antenna, OTA or EMC measurement methods.
The core recommended practice for antenna measurements.
Emission and immunity measurements in fully anechoic rooms.
Validation of test sites, including fully anechoic rooms.
TRP and TIS measurements for wireless devices.
Measuring the RF performance of absorber materials.
We define your measurements, lowest frequency and device size.
We plan absorber type, chamber size and quiet zone.
We build the shielded enclosure, absorbers and test system.
We coordinate independent quiet-zone validation.
If your question isn't answered here, ask our engineer directly.
In a semi-anechoic chamber the floor is reflective. In a fully anechoic chamber the floor is also covered with absorbers and there are no reflections at all.
The lowest frequency to be measured and the antenna size; lower frequencies need a larger chamber and absorbers.
It suits some emission tests. Most standard EMC tests are done in a semi-anechoic chamber.
We plan the positioner, antenna mast and cable penetrations together with the chamber.
By the lowest operating frequency and the target reflectivity. Lower frequencies need taller pyramids or ferrite-based hybrid absorbers, which directly affects chamber size.
Yes. With suitable absorbers, a target positioner and measurement system, a fully anechoic chamber can be designed for radar sensor and radar cross-section measurements.
In most cases, yes. Absorbers and test equipment are updated for the new frequency range and the quiet zone is re-validated by an independent body.
Tell us what you'll measure and over what frequency range; your survey and quote will be ready within 24 hours.
5G, radar and IoT antenna measurements.
For CE and certification testing.
Interference-free room for sensitive measurements.