Shielded High-Voltage Laboratory

We build shielded high-voltage laboratories to accurately measure weak signals such as partial discharge in cable, transformer and insulator testing.

  • Low noise for partial discharge measurement
  • Grounding and safety planning
  • Large-volume structure with special doors
  • High voltageTest environment
  • Partial dischargeSensitive measurement
  • ShieldedLow noise
Get a Quote for a High-Voltage LaboratoryA tailored quote and site survey appointment within 24 hours

or message us on WhatsApp

What is a high-voltage laboratory?

Sensitive Measurement at High Voltage

Partial discharge signals measured in high-voltage tests are very weak. Outside radio signals and mains noise can make these measurements impossible.

A shielded laboratory cuts out outside noise; grounding, safety clearances and doors for large equipment are custom-designed for the project.

Low Noise

Weak signals are measured accurately.

Shielded Volume

Outside signals don't enter the lab.

Safe Design

Grounding and clearances are planned.

Large Doors

Heavy equipment gets in easily.

Options

Three Options for Your Needs

Let Us Help You Choose

Test Cell

Cell for component testing.

Laboratory Hall

For transformer and cable testing.

Control Room

Shielded control area for measurement.

Technical specifications

Typical Technical Values

Values are defined per project. We give the exact figures in writing in the quote after the site survey.

Industries where it is used

ApplicationPartial discharge, withstand voltage tests
ShieldingPer project, focused on low noise
GroundingDedicated grounding system
DoorLarge, sliding or folding
ReferenceIEC 60060, IEC 60270
Process

From First Meeting to Handover

  1. 1

    Free Site Survey

    We listen to your needs, inspect the site and measure the signals.

  2. 2

    Design and Quote

    We define the size and equipment and give you a firm quote.

  3. 3

    Manufacturing and Installation

    We manufacture the parts, build the room and connect the services.

  4. 4

    Testing and Handover

    We test the room to the standard and deliver it with a report.

Frequently asked questions

Frequently Asked Questions About High-Voltage Laboratories

If your question isn't answered here, ask our engineer directly.

PhoneWhatsApp

Why is shielding needed?

Partial discharge measurements are very sensitive; outside noise spoils them. Shielding cuts this noise out.

What determines the laboratory size?

Test voltage, equipment size and safety clearances are assessed together.

Can an existing hall be converted?

In most cases, yes. Building height and floor are inspected during the survey.

Do you also do the grounding?

We plan a grounding system compatible with the shielding as part of the project.