Faraday Cage and Shielded Enclosure

We custom-build and install metal-clad cages and cabinets that keep outside signals out and inside signals in.

  • Custom-sized, from desktop enclosure to full room
  • Modular panels: movable and expandable
  • Independent acceptance test
  • 60–120 dBSignal blocking
  • ModularDismantled, moved
  • TestedDelivered with a report
Get a Quote for a Faraday CageA tailored quote and site survey appointment within 24 hours

or message us on WhatsApp

What is a Faraday cage?

Not Just a Metal Box, an Independently Tested Environment

A Faraday cage is a space completely enclosed by a conductive surface. Electromagnetic waves from outside stop at this surface, and signals emitted by devices inside cannot get out.

The real difference is in the details: if the door, ventilation, power and cable penetrations aren't done right, the cage doesn't work. We solve every penetration with dedicated parts, and independent acceptance testing shows the result.

Signal Isolation

Phone and Wi-Fi signals can't get in.

Custom-Built

Custom-sized, from cabinet to room.

Modular Build

Dismantled and moved easily.

Independent Acceptance

Performance is documented in a report.

Options

Three Options for Your Needs

Let Us Help You Choose

Desktop Enclosure

Desktop enclosure for small devices.

Walk-In Enclosure

Single-person, quickly installed cabin.

Shielded Room

Modular room for teamwork.

Technical specifications

Typical Technical Values

Values are defined per project. We give the exact figures in writing in the quote after the site survey.

Signal attenuation60–120 dB (as required)
Frequency range10 kHz – 18 GHz, optional 40 GHz
ConstructionGalvanized steel or copper modular panels
DoorSingle or double leaf, gasketed
Independent acceptance testEN 50147-1 or IEEE 299
What makes a cage work

A Faraday Cage Is Only as Strong as Its Weakest Point

Not every box with metal walls is a Faraday cage. Signals rarely leak through the walls; they get out through the door gap, a ventilation opening, a power cable or a hole drilled after installation. That's why the penetrations, not the panels, decide how well a cage performs.

We solve every penetration with purpose-built parts: power and signal lines pass through filters, air through honeycomb vent panels, and data through fiber optic waveguides. Doors close on double rows of RF gaskets, and panel joints are bonded for continuous contact. Independent acceptance testing shows the result, not an estimate.

  • Gasketed door

    Double RF gaskets seal the door gap.

  • Honeycomb ventilation

    Air gets through, signals don't.

  • Filtered power entry

    Power lines carry no signals in or out.

  • Fiber data penetration

    Network connections without breaching the shield.

  • Continuous panel joints

    No gaps between panels.

  • Independent acceptance

    Report to EN 50147-1 or IEEE 299.

Test standards

The Standards Behind Our Numbers

An independent accredited body measures and reports how much signal your cage blocks, using internationally recognized methods.

  • EN 50147-1

    Shielding effectiveness of shielded enclosures; the most widely used method in Europe.

  • IEEE 299

    US-origin test standard for shielded enclosures, often required in tenders.

  • MIL-STD-285

    The older military method replaced by IEEE 299, still cited in legacy specifications.

  • NSA 94-106

    Security specification used for high-performance shielded enclosures.

  • ISO/IEC 17025

    Infrastructure requirements for forensic and test laboratories.

Process

From First Meeting to Handover

  1. 1

    Needs and Survey

    We pin down the use case, device size and ambient signals.

  2. 2

    Size and dB Selection

    We define the cage type, door and required attenuation.

  3. 3

    Manufacture and Assembly

    We build the panels, assemble the cage and connect services.

  4. 4

    Independent Acceptance

    We coordinate independent acceptance testing and hand over the report.

Frequently asked questions

Frequently Asked Questions About Faraday Cages

If your question isn't answered here, ask our engineer directly.

PhoneWhatsApp

Is there a difference between a Faraday cage and a shielded room?

They work on the same principle. Small, simple structures are usually called cages; larger structures you work inside are called shielded rooms.

Does a phone get no signal at all inside?

In a properly built cage, mobile network, Wi-Fi and Bluetooth signals cannot get in; independent acceptance testing at handover proves it.

Can the cage be moved?

Modular panels can be dismantled and reassembled at the new location. Re-measurement is recommended after installation.

What does the price depend on?

Size, required dB level, frequency range, door type and interior equipment determine the price.

Is this the same as a lightning-protection Faraday cage?

No. The conductive mesh used for lightning protection on buildings is sometimes also called a Faraday cage. Our cages are shielded enclosures and rooms that isolate devices and workspaces from electromagnetic signals.

Which frequencies does a Faraday cage block?

Typically 10 kHz to 18 GHz, with an option up to 40 GHz. The attenuation achieved at each frequency is documented in the independent acceptance report.

Can power and internet be brought into the cage?

Yes. Power comes in through a filtered entry and internet through a fiber optic penetration, so the cage's shielding performance isn't compromised.

Faraday cage

Free Site Survey for Your Faraday Cage

Tell us what the cage is for and roughly how big it needs to be; your survey and quote will be ready within 24 hours.

Related Solutions

All Solutions

Get a Quote

Step 1 / 2 · Your Project

What kind of room do you need?
Approximate size