Desktop Enclosure
Desktop enclosure for small devices.
We custom-build and install metal-clad cages and cabinets that keep outside signals out and inside signals in.
A Faraday cage is a space completely enclosed by a conductive surface. Electromagnetic waves from outside stop at this surface, and signals emitted by devices inside cannot get out.
The real difference is in the details: if the door, ventilation, power and cable penetrations aren't done right, the cage doesn't work. We solve every penetration with dedicated parts, and independent acceptance testing shows the result.
Phone and Wi-Fi signals can't get in.
Custom-sized, from cabinet to room.
Dismantled and moved easily.
Performance is documented in a report.
Desktop enclosure for small devices.
Single-person, quickly installed cabin.
Modular room for teamwork.
Values are defined per project. We give the exact figures in writing in the quote after the site survey.
Industries where it is used
| Signal attenuation | 60–120 dB (as required) |
|---|---|
| Frequency range | 10 kHz – 18 GHz, optional 40 GHz |
| Construction | Galvanized steel or copper modular panels |
| Door | Single or double leaf, gasketed |
| Independent acceptance test | EN 50147-1 or IEEE 299 |
Not every box with metal walls is a Faraday cage. Signals rarely leak through the walls; they get out through the door gap, a ventilation opening, a power cable or a hole drilled after installation. That's why the penetrations, not the panels, decide how well a cage performs.
We solve every penetration with purpose-built parts: power and signal lines pass through filters, air through honeycomb vent panels, and data through fiber optic waveguides. Doors close on double rows of RF gaskets, and panel joints are bonded for continuous contact. Independent acceptance testing shows the result, not an estimate.
Double RF gaskets seal the door gap.
Air gets through, signals don't.
Power lines carry no signals in or out.
Network connections without breaching the shield.
No gaps between panels.
Report to EN 50147-1 or IEEE 299.
An independent accredited body measures and reports how much signal your cage blocks, using internationally recognized methods.
Shielding effectiveness of shielded enclosures; the most widely used method in Europe.
US-origin test standard for shielded enclosures, often required in tenders.
The older military method replaced by IEEE 299, still cited in legacy specifications.
Security specification used for high-performance shielded enclosures.
Infrastructure requirements for forensic and test laboratories.
We pin down the use case, device size and ambient signals.
We define the cage type, door and required attenuation.
We build the panels, assemble the cage and connect services.
We coordinate independent acceptance testing and hand over the report.
If your question isn't answered here, ask our engineer directly.
They work on the same principle. Small, simple structures are usually called cages; larger structures you work inside are called shielded rooms.
In a properly built cage, mobile network, Wi-Fi and Bluetooth signals cannot get in; independent acceptance testing at handover proves it.
Modular panels can be dismantled and reassembled at the new location. Re-measurement is recommended after installation.
Size, required dB level, frequency range, door type and interior equipment determine the price.
No. The conductive mesh used for lightning protection on buildings is sometimes also called a Faraday cage. Our cages are shielded enclosures and rooms that isolate devices and workspaces from electromagnetic signals.
Typically 10 kHz to 18 GHz, with an option up to 40 GHz. The attenuation achieved at each frequency is documented in the independent acceptance report.
Yes. Power comes in through a filtered entry and internet through a fiber optic penetration, so the cage's shielding performance isn't compromised.
Tell us what the cage is for and roughly how big it needs to be; your survey and quote will be ready within 24 hours.
Interference-free room for sensitive measurements.
Room that isolates evidence devices from signals.
We measure performance and report it.