Protected Cabinet
Protected cabinet for a single rack.
We build shielded volumes that protect command centers and critical data rooms against strong electromagnetic pulses.
An electromagnetic pulse (EMP) is a very strong field that forms in a very short time and can permanently damage electronic circuits. The type that forms at high altitude (HEMP) affects a very wide area.
A protected room encloses critical systems in a shielded volume. Every power, data and air line entering the room is fitted with special protectors that stop the pulse.
A strong pulse doesn't reach the systems.
Critical systems keep running.
Pulse protectors on every entry.
Performance is documented in a report.
Protected cabinet for a single rack.
Protected room for command equipment.
Multi-room, integrated protected facility.
Values are defined per project. We give the exact figures in writing in the quote after the site survey.
Industries where it is used
| Design basis | MIL-STD-188-125 |
|---|---|
| Signal attenuation | 80 dB and above |
| Line protection | Pulse filters and surge arresters |
| Door | Pulse-resistant shielded door |
| Independent acceptance test | Per the project specification |
A high-altitude electromagnetic pulse (HEMP) may look like a single event, but it has three components. E1 is an extremely fast pulse that rises in nanoseconds and goes straight for electronic circuits. E2 behaves much like lightning, while E3 is a slow component lasting seconds that induces currents in long power lines.
The pulse usually gets in through the cables entering the building, not through the walls. That's why a protected room combines a continuous shield with surge filters and arresters on every power and signal line. Data comes in over fiber, and doors and ventilation are sealed with pulse-rated parts, so critical systems keep running during and after the event.
Nanosecond rise time, targets electronics.
Lightning-like effect, handled by arresters.
Induces currents in long power lines.
Every surface sealed without gaps.
Power through filters, data over fiber.
Critical systems stay up after the pulse.
We design protection to the military and international standards your project specification calls for.
Design and verification of HEMP protection for fixed facilities.
HEMP protection for transportable systems and containers.
Description of the HEMP environment and its radiated pulse.
Test methods for protective devices against conducted HEMP disturbances.
HEMP protection methods and installation guidelines for civil systems.
We identify the systems to protect and the level required.
We plan the shield, surge filters, arresters and penetrations.
We build the room and route every line through protected entries.
We coordinate independent acceptance testing against the specification.
If your question isn't answered here, ask our engineer directly.
No. It is usually required in defense, government and critical infrastructure facilities. The need is determined by a risk assessment.
Yes. The protected room is built as an independent volume inside the building.
Air passes through honeycomb filters, and power lines enter the room through pulse-protection filters.
The main reference is MIL-STD-188-125. Additional requirements are added per the project specification.
E1 is the fast component that rises in nanoseconds and hits electronics directly. E2 resembles lightning, and E3 is a slow component lasting seconds that induces currents in long power lines. A protection design addresses all three.
Every power and signal line passes through a surge filter and arrester at the shield wall. Data links use non-conductive fiber optic cable, so the pulse can't ride in on the cabling.
Yes. Shielded containers and protected cabinets can be designed to MIL-STD-188-125-2, which covers transportable systems.
Tell us which systems need protecting and how the facility is laid out; your survey and quote will be ready within 24 hours.
Room that prevents information leakage.
Interference-free room for sensitive measurements.
Portable secure workspace.