EMP / HEMP Protected Room

We build shielded volumes that protect command centers and critical data rooms against strong electromagnetic pulses.

  • Design based on MIL-STD-188-125
  • Pulse-protection filters on every line
  • Critical systems keep running without interruption
  • HEMPPulse protection
  • ≥ 80 dBSignal blocking
  • CriticalSystem security
Get a Quote for an EMP / HEMP Protected RoomA tailored quote and site survey appointment within 24 hours

or message us on WhatsApp

What is an EMP / HEMP protected room?

One Pulse Can Stop All Electronics

An electromagnetic pulse (EMP) is a very strong field that forms in a very short time and can permanently damage electronic circuits. The type that forms at high altitude (HEMP) affects a very wide area.

A protected room encloses critical systems in a shielded volume. Every power, data and air line entering the room is fitted with special protectors that stop the pulse.

Pulse Protection

A strong pulse doesn't reach the systems.

Uninterrupted Operation

Critical systems keep running.

Protected Lines

Pulse protectors on every entry.

Independent Acceptance

Performance is documented in a report.

Options

Three Options for Your Needs

Let Us Help You Choose

Protected Cabinet

Protected cabinet for a single rack.

Protected Room

Protected room for command equipment.

Protected Facility

Multi-room, integrated protected facility.

Technical specifications

Typical Technical Values

Values are defined per project. We give the exact figures in writing in the quote after the site survey.

Design basisMIL-STD-188-125
Signal attenuation80 dB and above
Line protectionPulse filters and surge arresters
DoorPulse-resistant shielded door
Independent acceptance testPer the project specification
How the pulse hits

A Pulse Reaches Your Facility in Three Stages

A high-altitude electromagnetic pulse (HEMP) may look like a single event, but it has three components. E1 is an extremely fast pulse that rises in nanoseconds and goes straight for electronic circuits. E2 behaves much like lightning, while E3 is a slow component lasting seconds that induces currents in long power lines.

The pulse usually gets in through the cables entering the building, not through the walls. That's why a protected room combines a continuous shield with surge filters and arresters on every power and signal line. Data comes in over fiber, and doors and ventilation are sealed with pulse-rated parts, so critical systems keep running during and after the event.

  • E1 component

    Nanosecond rise time, targets electronics.

  • E2 component

    Lightning-like effect, handled by arresters.

  • E3 component

    Induces currents in long power lines.

  • Continuous shield

    Every surface sealed without gaps.

  • Protected penetrations

    Power through filters, data over fiber.

  • Business continuity

    Critical systems stay up after the pulse.

Standards

The Standards Behind EMP / HEMP Protection

We design protection to the military and international standards your project specification calls for.

  • MIL-STD-188-125-1

    Design and verification of HEMP protection for fixed facilities.

  • MIL-STD-188-125-2

    HEMP protection for transportable systems and containers.

  • IEC 61000-2-9

    Description of the HEMP environment and its radiated pulse.

  • IEC 61000-4-24

    Test methods for protective devices against conducted HEMP disturbances.

  • IEC 61000-5-x

    HEMP protection methods and installation guidelines for civil systems.

Process

From First Meeting to Handover

  1. 1

    Threat and Criticality Review

    We identify the systems to protect and the level required.

  2. 2

    Protection Design

    We plan the shield, surge filters, arresters and penetrations.

  3. 3

    Installation

    We build the room and route every line through protected entries.

  4. 4

    Verification

    We coordinate independent acceptance testing against the specification.

Frequently asked questions

Frequently Asked Questions About EMP / HEMP Protected Rooms

If your question isn't answered here, ask our engineer directly.

PhoneWhatsApp

Does every facility need EMP protection?

No. It is usually required in defense, government and critical infrastructure facilities. The need is determined by a risk assessment.

Can it be built in an existing building?

Yes. The protected room is built as an independent volume inside the building.

How are cooling and power provided?

Air passes through honeycomb filters, and power lines enter the room through pulse-protection filters.

Which standard is used?

The main reference is MIL-STD-188-125. Additional requirements are added per the project specification.

What's the difference between E1, E2 and E3?

E1 is the fast component that rises in nanoseconds and hits electronics directly. E2 resembles lightning, and E3 is a slow component lasting seconds that induces currents in long power lines. A protection design addresses all three.

How are cables entering the building protected?

Every power and signal line passes through a surge filter and arrester at the shield wall. Data links use non-conductive fiber optic cable, so the pulse can't ride in on the cabling.

Is transportable EMP protection possible?

Yes. Shielded containers and protected cabinets can be designed to MIL-STD-188-125-2, which covers transportable systems.

EMP / HEMP protected room

Free Site Survey for Your EMP / HEMP Protected Room

Tell us which systems need protecting and how the facility is laid out; your survey and quote will be ready within 24 hours.