SAC-10 · 10 m EMC Test Chamber

Heavy-load semi-anechoic chamber with a 10 m test distance for large equipment, vehicles and full compliance testing.

  • 10 m test distance, far-field measurement
  • Heavy-duty floor and large turntable
  • Suitable for full compliance and accreditation testing
  • 10 mTest distance
  • Heavy loadStrong floor and turntable
  • Full complianceAccreditation-ready
Get a Quote for a SAC-10 · 10 m EMC ChamberA tailored quote and site survey appointment within 24 hours

or message us on WhatsApp

What is a SAC-10 · 10 m EMC chamber?

Full-Scale Testing for Large Products

With its 10 m test distance, the SAC-10 is the most comprehensive semi-anechoic chamber, able to perform the far-field measurements the standards require.

Large industrial equipment, cabinet systems and vehicles are tested in this chamber. Test laboratories usually prefer this class for accreditation.

Far Field

The distance the standards require.

Heavy Load

Large products can be tested.

Accreditation

Suitable for full compliance testing.

Multiple Distances

3 m and 10 m tests together.

Options

Three Options for Your Needs

Let Us Help You Choose

Standard SAC-10

10 m chamber for large products.

Vehicle SAC-10

Full-vehicle chamber with dynamometer.

Laboratory SAC-10

For accredited laboratories.

Technical specifications

Typical Technical Values

Values are defined per project. We give the exact figures in writing in the quote after the site survey.

Test distance10 m (3 m optional)
Frequency range30 MHz – 18 GHz, optional 40 GHz
Site validationCISPR 16-1-4
TurntableHeavy load, flush with the floor
StandardsCISPR 32, CISPR 12, MIL-STD-461
A reference test site

A Test Site Built for Accreditation

In CISPR standards, radiated emission limits are mostly defined at 10 m. A SAC-10 lets you measure directly against those limits, with no distance correction. That's why it's the reference chamber for accredited test labs, manufacturers of large products and automotive suppliers.

At this scale, success depends not only on the absorbers but on the building itself. The ground plane, turntable pit depth, load capacity, large doors and control room all need planning from day one. We assess your building during the survey and, where needed, work alongside your architectural and structural teams.

  • Direct 10 m measurement

    Limits without distance correction.

  • 3 m and 10 m

    Two distances in one chamber.

  • Large products

    Vehicles, machinery and cabinets.

  • Hybrid absorbers

    Ferrite and pyramid combined.

  • Building integration

    Floor, doors and structure planned together.

  • Accreditation-ready

    Documents for your ISO/IEC 17025 file.

Standards

Which Tests Can You Run in a SAC-10?

We equip the chamber for your laboratory's accreditation scope and the product groups you'll test.

  • CISPR 16-1-4

    NSA and SVSWR site validation at 10 m and 3 m.

  • CISPR 32 / CISPR 11

    Emissions from IT, multimedia and industrial equipment.

  • CISPR 12

    Emissions from vehicles, boats and engine-driven devices.

  • ANSI C63.4

    10 m radiated measurements for FCC.

  • IEC 61000-4-3

    Radiated RF immunity testing.

  • ISO/IEC 17025

    General requirements for the competence of testing laboratories.

Process

From First Meeting to Handover

  1. 1

    Building and Scope Review

    We review your building, products and accreditation scope.

  2. 2

    Engineering Design

    We design the chamber, absorbers, floor and turntable.

  3. 3

    Site Installation

    We install the chamber and equipment and integrate the system.

  4. 4

    Validation and Documentation

    We coordinate independent validation at 10 m and 3 m.

Frequently asked questions

Frequently Asked Questions About SAC-10 · 10 m EMC Chambers

If your question isn't answered here, ask our engineer directly.

PhoneWhatsApp

How much space does a SAC-10 need?

The chamber requires a large volume; building height and floor are assessed during the survey.

Can vehicle tests be performed?

Yes. It can be designed for full-vehicle testing with a dynamometer and a large door.

Is it suitable for accreditation?

The chamber is validated to the standard by an independent body; the laboratory obtains accreditation separately.

Is a new building required?

It can be built in an industrial building of suitable height; if needed, we support the building design.

Can 3 m tests also be run in a SAC-10?

Yes. With adjusted antenna and product positions, the chamber is also independently validated at 3 m, so you can test against both 10 m and 3 m limits.

How much load can the turntable carry?

Capacity is set by your products. Smaller turntables suit standard products, while vehicles and heavy machinery need high-capacity turntables set into the floor.

How long does the project take?

It depends on building preparation and chamber size. After the survey, we give you a clear schedule covering design, manufacture, installation and validation.

SAC-10 · 10 m EMC chamber

Free Site Survey for Your SAC-10 · 10 m EMC Chamber

Tell us about your building and the product groups you'll test; your survey and quote will be ready within 24 hours.

Related Solutions

All Solutions

Get a Quote

Step 1 / 2 · Your Project

What kind of room do you need?
Approximate size