Digital forensics · Shielded room

Cyber Security Room

Phones and computers under examination can't connect to the outside world; evidence is preserved intact.

  • Mobile network, Wi-Fi, Bluetooth, GPS and satellite signals can't get in
  • The device can't be wiped remotely, located or send data
  • Turnkey installation, test report at handover
≥ 100 dBsignal blocking level
8–12 weeksfrom survey to handover
4 typesenclosure, room, laboratory, container
Get a Quote for a Cyber Security RoomA tailored quote and site survey appointment within 24 hours

or message us on WhatsApp

What is a cyber security room?

Evidence Stays Exactly as It Entered the Room.

A cyber security room is a special laboratory where seized phones, tablets and computers are examined, and no wireless signal from outside can enter.

What sets it apart from an ordinary Faraday cage is that you can work inside comfortably for hours. Power, internet, ventilation and lighting are provided through special parts that don't break the room's signal isolation.

Why does it matter? If a seized phone connects to a network even once, its owner can wipe it remotely. This room eliminates that risk from the moment the device is received until the examination ends. On the way from the field to the lab, the Forensic Evidence Box and Shielded Container provide the same protection.

Zero Connectivity

Mobile network, Wi-Fi, Bluetooth and satellite signals can't get in.

Evidence Secured

The device can't be wiped remotely, and its data can't be sent out.

Tested Handover

How well the room blocks signals is measured and reported.

Modular Build

Installed in your existing building; moved or expanded if needed.

Which signals does it block?

Every Path a Device Could Use to Communicate Outside Is Closed.

Mobile Network (2G–5G)

700 MHz – 6 GHz

Remote wipe commands and SMS can't get through.

Wi-Fi

2.4 / 5 / 6 GHz

Cloud backup and wireless data transfer stop.

Bluetooth / BLE

2.4 GHz

Nearby device connections and “Find My” broadcasts stop.

GPS / GNSS

1.1 – 1.6 GHz

Location can't update and the device can't be tracked.

Satellite Connection

L / Ku band

Messages and data can't be sent via satellite.

AirDrop and UWB

3.1 – 10.6 GHz

Nearby file sharing is blocked.

How is the room built?

A Room Is Only as Secure as Its Weakest Point.

Signals usually leak not through the wall but through the door, ventilation and cable penetrations. That's why each is made with special parts that don't leak signals.

Room Cross-Section

The dashed turquoise line shows the boundary signals can't cross. Power, air and internet cross this boundary only through a filter, a special ventilation grille and fiber cable.

Waveguide ventilation Filtered powerand data entry RF-gasketed door Galvanized steel shell · six sides Examination station Outside signalOutside signal

Signal-Proof Door

Thanks to the copper gaskets on its edges, it doesn't leak signals when closed. Single or double leaf.

Signal-Proof Ventilation

A special honeycomb-shaped grille lets air through but not signals.

Filtered Power Entry

Filters that prevent signals leaking over the power cable.

Fiber Internet Connection

Analysis computers stay connected to the internet, while the device under examination can't connect.

Technical specifications

Technical Values Ready for Tender Specifications.

Request a Technical Specification Template
Signal blocking (shielding)≥ 100 dB
Frequency range10 kHz – 18 GHz
Measurement standardEN 50147-1 / IEEE 299
Wall constructionModular galvanized steel panels
DoorRF-gasketed, single or double leaf
VentilationSignal-proof honeycomb grille
PowerFiltered entry panel, 16–63 A
InternetFiber cable or filtered wired network
InteriorOffice-comfort finish, LED lighting
Delivery time8–12 weeks
Types and sizes

Four Types to Suit Your Needs.

Shielded Cabin

Single examination station, an add-on to an existing lab

2 × 2 × 2.3 mtypical internal size
  • 1 station
  • Fast assembly
  • Portable structure
Get a Quote
Most Popular

Cyber Security Room

Permanent digital forensics laboratory

4 × 3 × 2.6 mtypical internal size
  • 2–4 stations
  • Fiber data line
  • Air conditioning and lighting
Get a Quote

Laboratory Complex

Multi-unit organizations and central laboratories

Project-specificdepending on area and number of rooms
  • Shielded entry vestibule
  • Evidence store
  • Many stations
Get a Quote

Shielded Container

Field units and projects needing fast installation

ISO 20 / 40 ftstandard or high ceiling
  • Portable
  • Office interior
  • Generator compatible
Get a Quote
Process

From First Meeting to Handover, Step by Step.

  1. 1

    Survey

    We inspect your building and measure the signals.

  2. 2

    Design

    We define the layout and draw the 3D design.

  3. 3

    Manufacturing

    We manufacture panels and doors in our workshop.

  4. 4

    Installation

    We install the room and connect the services.

  5. 5

    Testing and Handover

    We measure signal blocking and deliver with a report.

  6. 6

    Maintenance

    We measure once a year and renew gaskets.

Sample project

An Example from a Room We Built.

All Projects
Public Security · Abu Dhabi

4-station digital forensics laboratory

It was installed modularly on the third floor of an existing building without floor reinforcement. Thanks to the shielded entry vestibule, the examination area stayed isolated even with the door open. Analysis computers were connected to the organization's network over a fiber line.

"We've eliminated the risk of evidence loss; we now start examinations straight away when we return from the field."Unit head · Cybercrime unit
112 dBmeasured signal blocking (1 GHz)
9 weeksfrom survey to acceptance measurement
4simultaneous examination stations
Price depends on size and number of stations

Site survey and preliminary design are free. A transparent quote listing every item separately; technical specification support for tenders.

Frequently asked questions

About the Cyber Security Room.

Can't find the answer you need? Ask our engineer directly.

PhoneWhatsApp

Are a cyber security room and a Faraday cage the same thing?

A cyber security room is a Faraday cage; the difference is that it's designed for forensic examination. With filtered power and data entry, ventilation, lighting and workstations, it is built as a laboratory you can work in for hours.

How many dB of signal blocking is enough?

dB shows how much the room weakens a signal. 100 dB means the outside signal is reduced to one ten-billionth. To reliably block phone and Wi-Fi signals, 80–100 dB is usually targeted; the exact value depends on the signal level in your building and your organization's specification.

Can it be installed in an existing building?

Yes. The room arrives in parts, is carried in through standard doors and installed inside an existing room. We check floor load capacity, ceiling height and power supply during the survey.

Can the internet be used inside the room?

Yes. Internet is brought in over signal-tight fiber cable or a filtered wired network. That way analysis computers are online while the device under examination can't make a wireless connection.

What does the price depend on?

Room size, required signal blocking level, number of doors, number of people working inside and whether the building is ready determine the price. After the survey we give a quote listing every item separately.

Do you prepare specifications for public tenders?

Yes. We share free of charge a draft technical specification covering the signal blocking level, measurement standard, door and penetration details.

Cyber security room

Leave No Room for Evidence Loss.

Tell us how many people will work and where you want the room; your free site survey and quote will be ready within 24 hours.

Get a Quote

Step 1 / 2 · Your Project

What kind of room do you need?
Approximate size