EMC Testing

IEC 61000-4-3: How Radiated Immunity Testing Works

The setup, levels and chamber requirements of IEC 61000-4-3, the test that measures a device's immunity to radio transmitters and mobile phones.

A device is constantly exposed to radio waves in the environment where it is used. Mobile phones, two-way radios, wireless networks and broadcast transmitters create electric fields of different frequencies and strengths around it. These fields can induce unwanted signals on the device's cables and circuits, leading to faulty measurements, communication dropouts or unexpected behaviour.

IEC 61000-4-3 is the basic standard used to measure the immunity of devices to such radiated radio-frequency fields. In this article we explain what the test measures, how levels and frequency range are set, why the test is carried out in a shielded, absorber-lined chamber, what field uniformity means and what to watch for in pre-testing.

What Does the Test Measure?

In the IEC 61000-4-3 test, the device is placed in a controlled electric field, and this field is swept step by step over a specified frequency range. At each frequency the behaviour of the device is monitored and evaluated against the performance criteria defined in the test plan. The aim is to see whether the device keeps working correctly near the radio transmitters it may encounter in real life.

To represent real communication signals, the test signal is usually amplitude modulated at 80 percent with a 1 kHz sine wave. This modulation raises the peak value of the signal and reveals the device's sensitivity to rectification effects. For some product standards and applications, different types of modulation such as pulse modulation may also be used.

Levels and Frequency Range

The standard defines test levels as field strengths: level 1 is 1 V/m, level 2 is 3 V/m, level 3 is 10 V/m and level 4 is 30 V/m. Level X is a value set specifically by the product standard. Products designed for residential and commercial environments are usually tested at 3 V/m, and those for industrial environments at 10 V/m.

The test usually starts at 80 MHz and extends to 6 GHz. At frequencies below 80 MHz, the cables connected to the device pick up the field more than the device itself, so this region is tested as RF conducted onto cables under IEC 61000-4-6. In certain frequency ranges, such as mobile communication bands, some product standards may require higher levels. We explain the conducted RF test in our article on IEC 61000-4-6.

  • Level 1: 1 V/m
  • Level 2: 3 V/m (common for residential and commercial environments)
  • Level 3: 10 V/m (common for industrial environments)
  • Level 4: 30 V/m
  • Level X: specific to the product standard

Why Is a Shielded Chamber Needed?

In the radiated immunity test, strong electric fields of tens of volts per metre are generated. If these fields were generated in the open, they would disturb nearby communication systems and breach radio frequency regulations. Signals from the outside environment would also affect the test result. For this reason the test is carried out in a shielded chamber cut off from the outside.

The inner surfaces of the chamber are lined with absorbers, so that waves reflected from the walls do not disturb the uniformity of the field in the test area. Radiated immunity tests are usually carried out in the semi-anechoic chamber also used for emission tests; in this case absorbers are also placed on the floor between the antenna and the test area, suppressing the floor reflection too.

What Is Field Uniformity?

For the test to be repeatable, the field strength in the plane where the device is placed must be as even as possible. The standard defines this plane, usually 1.5 m x 1.5 m in size, as the uniform field area. When most of the measurements at 16 points in this area stay within a specified tolerance, this shows the chamber is suitable for the test.

The field uniformity measurement is the basis of validating the chamber for the test and is made before testing begins. The values recorded in this measurement also determine the power level at which the test will be run at each frequency. Absorber performance, chamber size and antenna position directly affect field uniformity. We explain this measurement in detail in our article on field uniformity measurement.

Test System and Power Amplifier

A radiated immunity test system consists of a signal generator, a power amplifier, a transmitting antenna, field probes and control software. The most expensive and most critical part of the system is the power amplifier. The power needed to achieve the required field strength depends on frequency, antenna efficiency and the distance between the antenna and the test area, and at high levels can reach hundreds of watts.

When choosing an amplifier, not only today's test levels but also higher levels that may be needed in the future should be considered. Also, because modulation raises the peak value of the signal, the amplifier must be able to deliver this peak without going into saturation. During the test, the device is monitored from outside the chamber through cameras and fibre optic connections.

Why Do Devices Fail?

In the radiated immunity test, failures often come from cables. Long cables connected to the device behave like efficient antennas at certain frequencies, collecting the field and carrying this energy straight to the device's input circuits. Analogue sensor inputs, audio circuits and low-level measurement circuits are the circuits most sensitive to this kind of interference.

Housing openings, cables with poorly terminated shields and unfiltered inputs are also common causes of failure. A device failing the test does not necessarily mean a major design error; the problem is often solved with a filter component, a ferrite or correct termination of a cable shield. We explain cable shielding in detail in our article on cable shielding and ferrites.

What to Watch for in Pre-Testing

Because it requires a shielded chamber and a powerful amplifier, the radiated immunity test is one of the hardest to do in pre-testing. But even pre-tests in a compact chamber with a lower-power amplifier and a shorter antenna distance can reveal the device's weakest frequencies. Once these frequencies are known, targeted improvements can be made before the certification test.

The most important point in pre-testing is monitoring the device correctly during the test. Which function will be evaluated with which criterion should be defined in advance, and the monitoring setup should be built with fibre optic connections so as not to disturb the test field. See our article on the pre-compliance room for pre-test infrastructure and our solutions for electronics manufacturers for test infrastructure.

Frequently Asked Questions

What equipment is needed for the test?

A signal generator, power amplifier, transmitting antenna, field probes, control software and a shielded, absorber-lined chamber are needed.

What is the field uniformity measurement?

It is the measurement that verifies the field is sufficiently even in the plane where the device will be placed. It determines the chamber's suitability for the test and the required power levels.

Does a device failing mean a design error?

Not always. In most cases the problem is solved with small changes such as filtering, correct termination of the cable shield or using a ferrite.

Which level applies to residential products?

Products designed for residential and commercial environments are usually tested at 3 V/m. For industrial environments this value is usually 10 V/m.

Why is the range below 80 MHz tested separately?

At these frequencies the field is mostly picked up by cables connected to the device. That is why below 80 MHz is tested as conducted RF on cables under IEC 61000-4-6.

How is the device monitored during the test?

It is monitored from outside the chamber using cameras and fibre optic connections. Copper cables are avoided because they can disturb the test field.