What is an anechoic chamber?

A Quiet, Reflection-Free Space for Measurement

An anechoic chamber is a shielded enclosure lined with RF absorbers. The shield keeps outside signals out, and the absorbers soak up reflections inside, so the measurement antenna sees only what your device emits.

That lets you measure a product's emissions without broadcast radio, TV and cellular signals swamping the result. The same chamber can expose the product to a controlled, repeatable field to prove its immunity.

A chamber that performs is a system, not a box: the shielded enclosure, absorber lining, turntable, antenna mast, filtered power, penetrations and control room. Each one is chosen for the standards you test to, the frequency range you need and the size of the products you build.

No Outside Noise

The shield blocks ambient signals.

No Reflections

Absorbers swallow wall reflections.

Repeatable

Every test runs under the same conditions.

Standards-Ready

Validated against your test standard.

Chamber types

Which Test Needs Which Chamber?

Anechoic chambers differ mainly in whether the floor is a metal ground plane or fully lined with absorbers, and in the measurement distance. The right choice follows from the tests you run and the size of your products.

Most Popular

Semi-Anechoic Chamber (SAC)

Radiated emissions and immunity for CE and certification

3 / 5 / 10 mmeasurement distance
  • Metal ground plane
  • CISPR 32, EN 55032
  • Turntable and antenna mast
Explore

Fully Anechoic Chamber (FAR)

Antenna, OTA and above-1 GHz measurements

400 MHz – 40 GHztypical frequency range
  • Absorbers on every surface
  • Free-space conditions
  • Positioner-ready
Explore

Antenna Measurement Chamber

5G, radar, satellite and IoT antennas

Far-field · CATRdepends on the method
  • Near-field and compact range
  • Quiet-zone validation
  • OTA (TRP / TIS) ready
Explore

Sector-Specific Chambers

Automotive, military and aerospace testing

CISPR 25 · MIL-STDstandard-specific layout
  • ALSE method
  • MIL-STD-461G and DO-160
  • Ground-plane test bench
Explore
Getting the size right

What Sets the Size of Your Chamber

Chamber dimensions are never arbitrary. The measurement distance sets the length: in a 3 m chamber, absorber depth and service clearances are added to the gap between antenna and device.

The lowest operating frequency drives the absorber choice. Absorbers that perform well at low frequencies are deeper and eat into the usable volume; combining ferrite tiles with short hybrid absorbers keeps that loss down.

Finally, the size and weight of your products set the turntable diameter and load rating, and your building's clear height decides whether the antenna mast's 1–4 m scan will fit. That's why every project starts with a site survey.

  • Measurement distance

    3 m, 5 m or 10 m, depending on the standard.

  • Frequency range

    The lowest frequency dictates absorber depth.

  • Product size and weight

    Sets turntable diameter and load rating.

  • Building constraints

    Clear height, floor loading and access routes.

  • Immunity testing

    Required field strength sets amplifier power.

  • Workload

    Control room, prep area and storage needs.

Technical specifications

Typical Technical Values

Values depend on the chamber type and how you will use it. We confirm the exact figures in writing in the quote after the site survey.

Shielding effectiveness100 dB and above (EN 50147-1 / IEEE 299)
Frequency range30 MHz – 18 GHz, 40 GHz optional
Measurement distance3 m, 5 m or 10 m
AbsorbersFerrite tile, hybrid or pyramidal
Site validationNSA ±4 dB, SVSWR ≤ 6 dB
ImmunityIEC 61000-4-3 field uniformity
EquipmentFlush turntable, 1–4 m antenna mast
HandoverTest report and operator training
Standards

The Standards Your Chamber Serves

We design and validate the chamber around the site and setup requirements of the standards you test to.

  • CISPR 16-1-4

    Validation of the emissions test site: NSA and SVSWR acceptance criteria.

  • CISPR 32 / EN 55032

    Radiated and conducted emissions from multimedia equipment.

  • IEC 61000-4-3

    Radiated RF immunity testing and field uniformity calibration.

  • CISPR 25

    Emissions from vehicle electronic components (ALSE method).

  • MIL-STD-461G

    Emissions and susceptibility testing of military equipment.

  • CTIA / 3GPP OTA

    TRP, TIS and antenna efficiency for wireless devices.

Why Kemar EMC?

One Partner, Measured Results

Since 2011

More than 1,000 projects and installations in 14 countries.

Measured Handover

Every chamber is delivered with an acceptance test report.

Process

From First Meeting to Handover

  1. 1

    Free Site Survey

    We review your tests and measure your building and ambient noise.

  2. 2

    Design and Quote

    We size the chamber, choose absorbers and equipment, and quote.

  3. 3

    Manufacturing and Installation

    We build the shell and equipment and install with our own team.

  4. 4

    Validation and Handover

    Shielding, NSA and SVSWR are measured and reported.

Frequently asked questions

Frequently Asked Questions About Anechoic Chambers

If your question isn't answered here, ask our engineer directly.

PhoneWhatsApp

What is the difference between a semi-anechoic and a fully anechoic chamber?

A semi-anechoic chamber has a metal floor and reproduces an open-area test site; most radiated emissions testing for CE is done in one. A fully anechoic chamber also has absorbers on the floor, giving free-space conditions for antenna, OTA and above-1 GHz measurements.

Should I choose a 3 m or a 10 m chamber?

A 3 m chamber covers most needs for benchtop and mid-sized products and is the most economical option. A 10 m chamber suits large products, certain certification requirements and the highest measurement accuracy. A 5 m chamber is a balanced middle ground.

How much space does an anechoic chamber need?

It depends on the measurement distance and absorber type. A typical 3 m chamber is around 8–10 m long and 5–6 m high inside; 10 m chambers are far larger. We work out the exact dimensions for your building during the site survey.

Will a chamber fit in our existing building?

In most cases, yes. During the survey we measure clear height, floor loading and access routes and, where needed, adapt the chamber to your building through absorber selection.

How is compliance with the standard proven?

After installation we measure shielding effectiveness, NSA and SVSWR to CISPR 16-1-4 and, for immunity testing, field uniformity to IEC 61000-4-3. You receive a report you can use in your accreditation application.

Can you relocate or upgrade our existing anechoic chamber?

Yes. We relocate anechoic chambers, including those built by other manufacturers, and carry out modifications such as frequency range extension, absorber renewal and new equipment.

How long does delivery take?

It depends on the chamber size, absorber type and equipment. After the survey we quote with a week-by-week schedule covering manufacturing and installation.

Anechoic chambers

A Free Site Survey for Your Anechoic Chamber

Tell us what you test and how big your products are; your survey and quote will be ready within 24 hours.

Related Solutions

All Solutions

Get a Quote

Step 1 / 2 · Your Project

What kind of room do you need?
Approximate size