Antenna Measurement Chambers in the 5G Era: What to Look For

Higher frequencies have made antenna measurements more sensitive. What to look for when choosing a measurement chamber.

With 5G, the frequency range in which wireless devices are tested has widened both downwards and upwards. On one side, low bands around 600 MHz, and on the other, millimetre-wave bands above 24 GHz are used together in the same product family. What is more, in most 5G devices the antenna is no longer a separate part; it is an integral component of the board, the housing and sometimes the display.

This change directly affects the design of antenna measurement chambers. In this article we explain how frequency range, absorber material, measurement system and measurement method are chosen when planning a chamber for 5G measurements, how over-the-air (OTA) testing affects the chamber, and how the investment can be adapted to future bands.

What Changed in 5G Measurements?

5G frequency bands fall into two main groups. FR1 covers the bands between 410 MHz and 7.125 GHz and can be tested with measurement methods similar to previous generations. FR2 consists of millimetre-wave bands above 24 GHz, where both propagation losses and the structure of the antennas are very different. A measurement chamber that can handle both of these worlds requires careful design choices.

The second big change is that the antenna has become inseparable from the device. In FR2 devices, antenna arrays are integrated directly into the module, and measuring through a conventional connector is often impossible. So parameters such as transmitter power, receiver sensitivity and beam performance have to be measured over the air, that is with OTA methods. This places the measurement chamber at the centre of the test chain.

How Does Frequency Range Determine Chamber Size?

The most important factor determining the size of an anechoic chamber is the lowest frequency to be measured. At low frequencies the wavelength is longer, so the absorbers need to be thicker, meaning longer pyramids, to suppress reflections sufficiently. This reduces the inner volume and increases the outer dimensions of the chamber for the same usable space. The distance needed to meet the far-field condition for antennas also grows at low frequencies.

At high frequencies the picture is reversed. In millimetre-wave bands the wavelength drops to a few millimetres, but the far-field distance of large antenna arrays can become very long. For this reason, methods such as compact range or near-field are preferred for FR2 measurements instead of direct far-field. Defining the lowest and highest frequency of the chamber together is the first step to the right size.

Choosing the Absorber Material

In antenna measurement chambers, the role of the absorber is to minimise reflections from the walls, ceiling and floor, creating a quiet zone around the antenna being measured. The reflection level in this zone directly determines measurement accuracy. Pyramid absorbers perform well over a wide frequency range, but their size is chosen according to the lowest frequency.

In millimetre-wave bands, the surface quality and mounting precision of absorbers become more important. Small gaps between absorbers, cable penetrations and metal parts of the measurement system can create noticeable reflections at these frequencies. For this reason the positioner, antenna mast and cable routes should also be covered with absorber or designed to reduce reflection. We compare absorber types in our article on ferrite tiles and pyramid absorbers.

Measurement System and Positioners

An antenna measurement chamber forms a whole with the measurement system placed inside it. The positioner that rotates the device to different angles, the mast or arch carrying the measurement antenna, RF cables, switching units and measurement software must be compatible with the chamber design. For example, if the metal body of a positioner sits inside the quiet zone, it can cause reflections that distort the measurement results.

For over-the-air performance tests of wireless devices, test plans published by operators and industry bodies are taken into account. CTIA test plans and 3GPP OTA methods define at which angles, at what resolution and with which uncertainty targets the measurement is performed. We describe total radiated power and total isotropic sensitivity measurements in our article on OTA testing: TRP and TIS.

Choosing the Measurement Method

In 5G measurements, the right chamber depends on the measurement method to be used. The direct far-field method is the simplest approach, but with large antennas and high frequencies it requires very long chambers. The compact range method creates a plane wave with a reflector, meeting the far-field condition at a much shorter distance, and is widely used in FR2 measurements.

In the near-field method, the field distribution measured close to the antenna is converted to the far field by mathematical transformation. This method can deliver high accuracy in very small chambers, but measurement time and software infrastructure are more complex. We cover the details of these methods in our articles on compact range and near-field measurement, and FR2-specific challenges in our article on mmWave measurement challenges.

Flexibility for Future Bands

Developments in wireless technology may require a chamber built today to measure new bands within a few years. Later 3GPP releases extended FR2 bands to higher frequencies, and technologies such as Wi-Fi 7 have started using the 6 GHz band heavily. When investing, it is important to take into account not just today's products but also the product roadmap for the next five years.

There are several ways to provide flexibility. Modular mounting of absorbers allows them to be replaced later with absorbers that perform better at higher frequencies. The positioner and antenna system can be chosen so that antennas for new frequency bands can be fitted. The chamber's shielding, however, should be designed from the start to perform adequately over a wide frequency range, because improving shielding afterwards is the hardest part.

Shielding and a Quiet Environment

An antenna measurement chamber must block not only reflections inside but also signals coming from outside. Base stations, Wi-Fi networks and other transmitters in a city centre can distort results, especially in receiver sensitivity measurements. For this reason the shielding effectiveness of the chamber should be determined according to the lowest signal level to be measured.

Cable penetrations, ventilation filters and door gaskets are critical points for maintaining shielding performance. Fibre optics or filtered penetrations should be used for the control cables of the measurement system, and unnecessary electronic equipment should not be kept inside the chamber. You can find chamber options on our antenna measurement chamber page and our solutions for the telecom sector on our telecom and 5G page.

Frequently Asked Questions

Which chamber is sufficient for 5G FR1?

For FR1 bands, a correctly sized standard fully anechoic chamber is sufficient for most measurements. Chamber size is determined by the lowest frequency to be measured and the antenna size.

Why is compact range preferred for FR2 measurements?

In millimetre-wave bands, the far-field distance of large antenna arrays becomes very long. A compact range meets this condition at a much shorter distance using a reflector.

Can an antenna chamber also be used for EMC tests?

Some emission measurements can be made, but most EMC standards require a semi-anechoic chamber and specific validation conditions. The two needs call for different chamber designs.

Can the chamber be adapted to future bands?

The operating range can be extended by replacing absorbers, antennas and the measurement system. Shielding, however, must be designed from the start for a wide frequency range.

Why has OTA testing become mandatory?

In 5G devices, especially in FR2, antennas are integrated into the module, so measuring through a connector is often impossible. Performance is therefore measured over the air.