Faraday Bag, Shielded Box or Shielded Room?
Which stage and purpose the Faraday bag, shielded evidence box and shielded room each serve in protecting electronic evidence.
What digital forensics labs preparing for ISO/IEC 17025 accreditation should watch for in their working environment, equipment and records.
Whether a digital forensics report can be used with confidence in court depends on the competence of the laboratory that prepared it and the reliability of its processes. ISO/IEC 17025 accreditation shows, verified by an independent body, that a laboratory is technically competent and produces valid results. That is why more and more digital forensics laboratories are aiming for accreditation.
The accreditation process is often associated with methods, staff competence and quality documents. But infrastructure is also an important part of the process. In this article we explain what accreditation proves, what the standard requires of the working environment and equipment, the role of the shielded room in this process, how records should be kept and what to watch for when setting up a laboratory.
ISO/IEC 17025 is an international standard defining general requirements for the competence of testing and calibration laboratories. Accreditation of a laboratory to this standard shows that its management system, staff, methods, equipment and working environment are organised to produce valid and reliable results. In Turkey, accreditation is carried out by the national accreditation body.
For digital forensics, accreditation proves that the laboratory handles digital evidence while preserving its integrity and that analysis results are repeatable and traceable. This increases confidence in the laboratory's reports in court and makes it easier for the laboratory to defend its processes if its reports are challenged. Accreditation is granted for specific methods within its scope.
ISO/IEC 17025 requires the laboratory's facilities and environmental conditions to be suitable so that they do not adversely affect the validity of its activities. The standard requires environmental conditions that could affect results to be identified, monitored, controlled and recorded. In digital forensics, the foremost of these conditions is that the devices being examined do not connect to the outside world.
The shielded room is a concrete answer to this requirement. The presence of the room shows that the laboratory has brought under control the risk of mobile devices changing by connecting to a network. But in an audit, what matters is not just that the room exists but that its performance is documented. An up-to-date measurement report showing how much attenuation the room provides at which frequencies is the evidence that this requirement is met.
The standard requires equipment that affects results to be suitable, calibrated where necessary and recorded. In digital forensics, this equipment consists of examination software and hardware, write blockers, imaging devices and storage systems. This equipment needs to be validated, its versions recorded and checked regularly.
The shielded room can also be treated as a piece of equipment in this respect. Measuring the room's performance at set intervals, recording the results and planning the next measurement date should be part of the quality system. The measurement should be made with calibrated equipment and a traceable method, and the report added to the quality documents.
One of the cornerstones of accreditation is that every action in the laboratory is traceable. In digital forensics, this means recording every step of a piece of evidence from entering to leaving the laboratory: who received it, where it was stored, who examined it and when, which operations were carried out. These records prove that the chain of custody is unbroken.
The shielded room can be a natural part of this record system. Recording entries and exits with a card access system, documenting operations inside the room with cameras and adding the room's performance measurements to quality records provide strong evidence in an audit. International guidelines on collecting and preserving digital evidence also support this approach.
When setting up a laboratory aiming for accreditation, infrastructure decisions should be made with accreditation requirements in mind. The size of the shielded room should be set according to the laboratory's expected workload and number of staff; the room's performance should cover the frequency bands that all devices being examined could use. The acceptance measurement made after installation becomes one of the first documents in the accreditation file.
The overall layout of the laboratory also matters. Evidence intake, storage, examination and reporting areas should be planned to make the flow of evidence and access control easier. A double-door vestibule for entering the shielded room keeps protection uninterrupted while evidence is transferred. We explain why the room is needed in our article why a cyber security room is needed.
It is also possible to add a shielded room to a laboratory that is already operating. Modular shielded rooms can be installed inside an existing space with minimal impact on the laboratory's work. During installation, examinations can continue in another area or with temporary solutions. If space is limited, starting with single-station enclosures is also an option.
After the room is added, the laboratory's procedures should be updated and staff trained in the new workflow. The room's description, rules of use and maintenance and measurement plan should be added to the quality documents. These updates ensure the room is assessed as an integral part of the system at the next accreditation audit.
In an accreditation audit, questions about infrastructure usually cover how the room's performance is verified, how often measurements are made, how results are evaluated and what is done if performance drops. The answers to these questions should be in writing in the quality system and supported by records.
When preparing for the audit, check that the room's current measurement report, maintenance records, entry and exit records and staff training records are complete. Keeping these documents in order makes the audit easier and increases confidence in the laboratory's processes. For support with measurement and documentation, see our certificates page, and for our laboratory solutions, our digital forensics solutions page.
The standard does not directly require a shielded room, but it does require environmental conditions that could affect results to be controlled. For mobile device examinations, the most reliable way to achieve this control is a shielded room.
Most laboratories measure once a year. The exact frequency should be defined in the laboratory's quality system.
Yes. Modular rooms can be installed inside the existing space; if space is limited, single-station enclosures are a starting point.
Usually how the room's performance is verified, how often it is measured, how results are evaluated and what is done if performance drops.
All bands the devices being examined could use: cellular networks, Wi-Fi, Bluetooth, positioning and satellite communication bands.
They prove that the chain of custody is unbroken and that only authorised people entered the room. These records provide strong evidence in accreditation audits and in court.
Related Solutions
Your free site survey and quote will be ready within 24 hours.
Which stage and purpose the Faraday bag, shielded evidence box and shielded room each serve in protecting electronic evidence.
What new phones that can message via satellite mean for digital forensics labs, and what changes in signal isolation as a result.
Connecting a seized phone to a network even once can destroy the evidence. The basic rules for protecting evidence integrity.