What Is TEMPEST? Can Your Computer Be Eavesdropped From Outside?

Screens, keyboards and cables emit signals unintentionally. What TEMPEST protection is and which organizations need it.

The image you see on a computer screen, the keys you press on a keyboard or a document sent to a printer do not stay only inside the device. Electronic circuits emit weak electromagnetic signals related to the information they process while they work. These signals can be picked up from outside the building with suitable receivers and processing methods and turned back into meaningful information.

TEMPEST is the general name for measures that aim to prevent information leaking through these unintended emissions. In this article we explain how unintended emissions arise, which information is at risk, which methods provide protection, the standards within the NATO framework and who needs TEMPEST measures.

What Are Unintended Emissions?

In electronic devices, information is carried by currents and voltages that switch on and off very quickly. These changes radiate into the surroundings as electromagnetic energy from the device's cables, board traces and components. Part of this radiation is directly related to the information being processed; for example, the signal radiated from a display cable carries the pixel information of the image shown on the screen.

That such leakage can be captured in practice came to public attention through studies published in the 1980s. Since then, many studies have shown that information can be obtained from display cables, keyboards, printers and even power cables. Although the methods used have changed as technology developed, the basic risk has stayed the same.

Which Information Is at Risk?

In theory, any information processed electronically can leak through unintended emissions. In practice, the sources that attract most attention are screen images, keyboard input and printer output, because in these sources information is processed relatively slowly and regularly and is easier to reconstruct. Encryption devices themselves are also at risk at the moment they process unencrypted information.

The size of the risk depends on the value of the information, the emission level of the device, the distance an attacker can reach and other signals in the environment. In a busy office, the signals of many devices mix together and it becomes harder to distinguish the signal of a single device; however, this is not a definite obstacle for a determined and well-equipped attacker. We discuss risks in the corporate environment in our article on corporate espionage and electromagnetic leakage.

How Is Protection Provided?

There are three basic approaches to TEMPEST protection, and they are often used together. The first is to use low-emission equipment: equipment designed and tested to reduce emissions. The second is to keep equipment at a distance an attacker cannot reach, that is inside the secure zone. The third is to shield the environment.

A TEMPEST room protects all the equipment inside it together through shielding. This allows ordinary commercial equipment to be used inside the room. Power, data and ventilation lines entering the room are also passed through special filters, because they can carry information; data connections are usually made with fibre optics. We describe room-level protection options on our TEMPEST room page.

  • Use of low-emission (TEMPEST certified) equipment
  • Positioning equipment inside the secure zone
  • Shielding the environment and filtering all lines
  • Physical separation of red and black lines

The NATO Framework and Standards

In NATO member countries, TEMPEST measures are defined by documents in the SDIP series. SDIP-27 defines equipment emission levels at three levels, A, B and C, with level A the strictest. SDIP-28 covers the zoning method, and SDIP-29 contains rules on how systems processing classified information are installed within a facility.

The detailed contents of these documents may be classified and are shared with authorised organisations through national security authorities. In Turkey, testing, certification and evaluation activities in the TEMPEST field are carried out under the coordination of the relevant national institutions. We explain the levels in detail in our article on SDIP-27 levels.

Levels and Zones Work Together

Two concepts are used together in TEMPEST protection: levels, which show how much the equipment emits, and zones, which show the protection an area provides against the outside. Each area in a facility receives a zone number according to the distance a potential attacker outside could reach and the attenuation provided by the structure in between.

Matching these two concepts creates balanced and economical protection. In a zone that provides high protection against the outside, higher-emission equipment can be used, while in an unprotected area only the lowest-emission equipment is allowed. We explain in detail how the zoning method is reflected in a facility plan in our article on TEMPEST zoning.

Who Needs It?

Public institutions processing classified information, defence companies, embassies and critical infrastructure operators are the organisations that most need TEMPEST measures. For suppliers working on defence projects, these measures are often a contract requirement and a precondition for taking part in the project.

In the commercial world, companies holding high-value intellectual property, merger and acquisition information or strategic data may also turn to similar measures. For these organisations, shielding critical areas such as boardrooms or data rooms is usually enough instead of a full TEMPEST programme. We discuss this approach in our article on the secure meeting room.

What to Consider When Building a TEMPEST Room

A TEMPEST room requires more than an ordinary shielded room. In addition to shielding, red lines carrying classified information must be physically separated from black lines carrying encrypted or unclassified information, filters must be placed according to this separation, and the earthing system must be designed accordingly.

Acceptance of the room is completed with a shielding measurement and the evaluations required by the relevant security authorities. After installation, periodic measurement, access control and checks on equipment entering the room are essential for continued protection. Our solutions for defence projects are on our defence industry page.

Frequently Asked Questions

Is TEMPEST only a military issue?

No. Public institutions processing classified information, embassies and companies with high-value commercial information also take TEMPEST measures.

Can a screen signal be captured in an ordinary office?

With suitable equipment and at close range it is technically possible. The risk is assessed according to the value of the information, the equipment and the environment.

What is the difference between a TEMPEST room and a shielded room?

In a TEMPEST room, in addition to shielding, all lines are filtered so they cannot leak information, red and black lines are separated and a zone assessment is made.

What do SDIP-27 levels mean?

SDIP-27 defines equipment emission levels at three levels, A, B and C. Level A means the lowest emission, that is the strictest requirement.

Is using TEMPEST certified equipment enough?

The equipment level must match the zone of the area where it is used. Cabling, earthing and installation rules are also part of the protection.

Can an existing office be converted into a TEMPEST room?

In most cases yes. The conversion can be made by building a shielded structure inside the room and filtering all lines; suitability is determined by on-site survey and measurement.