Magnetic Shielding: Flickering Screens in Offices Near Transformers
Low-frequency magnetic fields cannot be stopped by ordinary shielding. We explain how magnetic shielding is done.
The door is the most common cause of lost performance in shielded rooms. We cover door types and why maintenance matters.
Once the walls, ceiling and floor of a shielded room are installed, they stay the same for years. The door, however, is opened and closed dozens of times a day, trolleys roll over it, its gaskets rub and its hinges flex over time. That is why most performance problems in shielded rooms come from the door, and the overall shielding value of the room is often limited by the value of the door.
In this article we explain why the shielded door is the most critical part of the room, which door types suit which use, how gasket choice affects performance, how the right size is determined and what maintenance is needed for a door to keep its day-one performance for years.
The performance of a shielded room is limited by the performance of its weakest point. Joints between wall panels are made once during installation and are permanent. The door, however, is the only part of the shield that is broken every time it opens and re-established every time it closes. When the door closes, electrical contact between leaf and frame is made by compressing the gaskets, and the quality of this contact directly determines shielding performance.
Over time, gaskets wear, get dirty or are crushed, hinges flex and the door leaf no longer seats in the frame as neatly as before. Each of these changes creates small openings around the door, and at high frequencies signals start to leak through these openings. If the walls perform at 100 dB while the area around the door drops to 60 dB, the real performance of the room is 60 dB.
In small and medium shielded rooms, the most common type is the manually operated hinged door. In these doors, a knife-edge profile on the edge of the leaf enters double rows of finger stock gaskets in the frame to make electrical contact. When adjusted correctly it delivers high performance, has a simple mechanical structure and is easy to maintain. Single-leaf and double-leaf versions are available.
In large test chambers and busy laboratories, automatic doors come to the fore. Sliding doors are pressed against the frame after closing by a pneumatic or mechanical mechanism, compressing the gaskets. In doors with inflatable seals, air is supplied to the seal after the door closes and contact is made by pressure. These doors provide high performance over large openings, but require an air supply and a control system.
Door selection cannot be considered separately from the type of gasket. Finger stock gaskets made of beryllium copper or stainless steel deliver high performance over a wide frequency range and are the most common solution in shielded room doors. Using double rows of finger stock keeps contact even if one row is damaged.
Knitted wire mesh and conductive elastomer gaskets are alternatives that need less maintenance and resist mechanical impact better, but their performance can be limited at very high frequencies. Gasket selection should consider the target frequency range, how often the door is used and the maintenance possibilities together. We explain gasket types in detail in our article on RF gasket types.
Door size should be set according to the largest equipment that will enter the room. In test chambers this may be a vehicle, an electronic rack or a large test setup. Not only the dimensions of the equipment itself but also those of the pallet truck or forklift used to move it must be taken into account.
As a door gets larger, its weight, cost and gasket length increase, and so does the maintenance it needs. In rooms where very large equipment enters rarely, it can be more economical to plan a small personnel door for daily use and a separate equipment door for large items. Threshold height also matters; for doors that heavy trolleys will pass through, threshold-free or ramped solutions should be preferred.
Shielded doors should be evaluated not only for electromagnetic performance but also for user safety. They must always be openable from the inside, allow quick evacuation in an emergency and include panic bar hardware where necessary. Automatic doors must have anti-trap sensors and a manual opening option.
Threshold-free or low-threshold door solutions suitable for disabled access are also available. In security rooms, the door can be integrated with a card access system, a door-open alarm and a logging system. The cables for these systems must also enter the room through filtered penetrations in the door frame.
With proper maintenance, a shielded door keeps its day-one performance for many years. Finger stock gaskets should be cleaned regularly, bent or broken fingers replaced and the surface of the knife-edge profile checked for oxidation. Hinges and the locking mechanism should be adjusted periodically so the leaf seats properly in the frame.
A drop in door performance is usually gradual and not visible to the eye. For this reason, scanning the area around the door specifically during the annual shielding measurement is recommended. A local drop found in the measurement can often be fixed just by replacing a few gaskets. We have collected detailed maintenance recommendations in our article on the shielded room maintenance schedule.
When the performance of an older shielded room drops, the first place to look is the door. In most cases, renewing the door's gaskets, hinges or locking mechanism rather than the whole room recovers much of the performance. If the door frame is seriously deformed, however, the door may need to be replaced entirely.
Replacement can be done by designing a new door that fits the existing frame dimensions, or by installing a complete new door system including the frame. Which option is suitable is determined by on-site inspection and measurement. For our maintenance and upgrade services, see our maintenance and modification page.
Yes. Pneumatically or electrically driven shielded doors are preferred especially in frequently used laboratories and large test chambers.
A check and adjustment at least once a year is recommended depending on usage. For heavily used doors, this can be more frequent.
Yes. Threshold-free or low-threshold shielded door solutions are available.
They should be replaced when bent, broken or oxidised fingers are seen. A performance drop around the door in the annual measurement is also a sign that replacement is needed.
Usually yes. Because the door is the only part of the shield that is constantly opened and closed, the room's real performance is often determined by the door's performance.
Yes. The gaskets and mechanism can be renewed, or a new door can be designed to fit the existing frame. Which option is suitable is determined by on-site inspection and measurement.