Modular Panels or a Welded Shielded Room? Pros and Limits
We compare shielded rooms built from bolted modular panels with welded steel rooms on performance, installation time, portability and cost.
What the 80, 100 or 120 dB values in shielded room quotes really mean, and what you should check when you compare quotes from suppliers.
The unit most often seen in shielded room quotes, specifications and measurement reports is the decibel: 80 dB, 100 dB, 120 dB. These values express how much the room attenuates a signal. But the decibel is not an ordinary unit and can be misleading if not read correctly. A 20 dB difference between two quotes may look small on paper, but in reality it means the signal is attenuated ten times more.
In this article we explain what a decibel is, how shielding values are calculated, how frequency and measurement method affect these values, how much shielding is enough for different applications and what to watch for when reading dB values in quotes and reports.
The decibel is a unit that expresses the ratio between two values on a logarithmic scale. In shielding, the two values are the signal level measured without the shield and the signal level measured with the shield. The logarithmic scale makes it possible to express ratios over a very wide range with convenient numbers. For example, a shield that reduces signal power ten billion times is expressed as 100 dB.
For field quantities such as electric field or magnetic field, every 20 dB means the field is reduced tenfold. For power, every 10 dB represents a tenfold reduction. So a 60 dB shield reduces the field a thousand times, and a 100 dB shield a hundred thousand times. The difference between 80 dB and 100 dB means the field is attenuated ten times more.
The performance of a shielded room varies with frequency. The same room can show 120 dB attenuation at one frequency and 60 dB at another. A shielding value given without stating at which frequency or over which frequency range it applies is therefore meaningless. The statement 'our room provides 100 dB shielding' says nothing until the question 'at which frequency?' is answered.
In general, shielded rooms show higher values at high frequencies than at low ones. Especially in the region from a few kilohertz to a few megahertz, magnetic field shielding is difficult for thin metal surfaces and values drop noticeably. That is why in specifications and reports values must be given separately for each frequency band.
The same room can give different results when measured with different methods. Standards such as EN 50147-1 and IEEE 299 define antenna distance, measurement points and how the reference measurement is taken in different ways. These differences can lead to results a few decibels apart in the same room.
So a shielding value should not be compared without stating which standard it was measured to. When evaluating quotes and reports, check whether the values were obtained by the same method. We explain the measurement methods in detail in our article on EN 50147-1 or IEEE 299.
A measurement report lists the values obtained at each frequency and each measurement point. These values should not be averaged; the room's real performance is equal to the lowest value measured. A room measuring 120 dB in the middle of the walls but 80 dB at the door edge is in practice an 80 dB room, because the signal will leak through the weakest point.
When reading reports, therefore, attention should be paid to the lowest value at each frequency and where it was measured. If the lowest value consistently appears at the same point, for example the door or a filter, that point needs improvement. This also determines where maintenance should focus.
Measuring very high shielding values means running into the limits of the measurement system itself. If the measurement system's dynamic range, that is the largest attenuation it can measure, is lower than the room's performance, the value in the report shows the limit of the measurement system rather than the room. In that case the report uses a phrase such as 'greater than 120 dB'.
This statement says that the room performs at least at that value, but the true value is unknown. A measurement of 120 dB and 'greater than 120 dB' are not the same thing. When comparing quotes, the dynamic ranges of the measurement systems must also be taken into account; sometimes a value that looks higher is simply the result of a more powerful measurement system.
The required shielding value depends on the application. To reliably block mobile phone and Wi-Fi signals, 60 to 80 dB is usually enough, but locations close to strong transmitters may need higher values. For digital forensics rooms the typical target is 80 to 100 dB across all mobile bands. In EMC test chambers, similar or higher values are required depending on measurement sensitivity.
TEMPEST and military applications usually require higher values and wider frequency ranges. Determining the level that is really needed is the most effective way to avoid unnecessary cost, because every extra decibel requires an increase in panel, door and filter quality. We share our recommendations for setting the right level in our specification writing guide.
The performance of a shielded room can decrease with time and use. Worn door gaskets, loosened panel joints, ageing filters and penetrations opened later all reduce measured values. This decline is usually gradual and cannot be seen by eye, but it shows up in periodic measurement.
It is therefore recommended to measure shielded room performance regularly and compare the results with previous measurements. When a noticeable drop is observed at a point, performance can usually be recovered by maintaining the gasket or connection at that point. For our measurement service, see our shielding measurement page.
Yes, if measured at the same frequency, by the same method and at the same point. Values measured at different frequencies or by different methods cannot be compared directly.
Yes. Gasket wear, loosened connections and new penetrations can reduce performance. Periodic measurement is therefore recommended.
Shielding low-frequency magnetic fields with thin metal surfaces is physically difficult. Target values for this region are therefore usually lower.
For field quantities, a 20 dB difference means the field is attenuated ten times more.
It shows that the room's performance is higher than the limit of the measurement system, but the true value could not be measured.
Usually 60 to 80 dB is enough. Higher values are targeted in locations close to strong transmitters or in critical applications such as forensic examination.
Related Solutions