Antenna Measurement Chambers in the 5G Era: What to Look For
Higher frequencies have made antenna measurements more sensitive. What to look for when choosing a measurement chamber.
Why antenna and device measurements get harder in 5G bands above 24 GHz, and what to watch for when choosing the chamber and absorbers.
5G's second frequency range (FR2) covers millimeter-wave bands above 24 GHz. At these frequencies the wavelength drops to a few millimeters; small imperfections in cables, connectors and even test fixtures noticeably affect the measurement.
In FR2 devices the antenna is also often embedded in a single module together with the radio chip. Since you can't connect a cable to the antenna, the whole measurement must be done over the air, the OTA method.
At high frequency, signals weaken much faster in air. The distance needed to meet the far-field condition also grows with antenna size and frequency. The measurement system ends up having to capture a very weak signal above the noise.
Compact antenna test range (CATR) systems have become common to solve this. A reflector creates a plane wave over a short distance, allowing far-field measurement without a large chamber.
At millimeter wave, absorber surface flatness and joints become important. Even a few poorly placed pieces can create measurable reflections. That's why FR2 chambers use fine-structured absorbers optimized for high frequency.
The chamber's shielding must also be sufficient at high frequency; door gaskets and penetrations should be tested at 40 GHz and above. These details are planned from the start in fully anechoic chamber design.
Not every company needs the largest chamber. A compact CATR chamber may be enough for R&D teams, and shielded test boxes for quick checks on the production line.
By reviewing your test plan and the parameters you want to measure, we recommend the right chamber size and equipment layout for telecom and 5G.
With CATR, a chamber a few meters long is often enough. If direct far-field measurement is required, a much longer distance is needed depending on antenna size.
Not directly if the absorbers, shielding and measurement system aren't suited to high frequency. Upgrade options are assessed during the survey.
Total radiated power (TRP), total isotropic sensitivity (TIS), beam steering and EVM are among the parameters measured.
Related Solutions
Your free site survey and quote will be ready within 24 hours.
Higher frequencies have made antenna measurements more sensitive. What to look for when choosing a measurement chamber.
The TEMPEST zoning approach, which classifies the area where equipment sits by its distance to a possible outside listening point in classified facilities.
The naming logic of the MIL-STD-461G tests that military equipment must pass, and the most requested CE102, RE102 and RS103 tests, in plain language.