Anechoic and Antenna Chamber Relocation

We dismantle your semi-anechoic, fully anechoic or antenna measurement chamber, move it to your new facility, rebuild it, and prove with measurements that it performs just as it did before the move.

  • NSA, SVSWR and shielding tests before and after the move
  • Complete teardown, including absorbers, turntable and mast
  • Chambers built by other manufacturers welcome
  • MeasuredBefore and after
  • Single sourceTeardown to rebuild
  • WorldwideInternational moves
Get a Quote for Chamber RelocationA tailored quote and site survey appointment within 24 hours

or message us on WhatsApp

Why a specialist move?

An Anechoic Chamber Doesn't Move Like an Ordinary Room

What makes an anechoic chamber valuable isn't just its shield. The absorber layout, a turntable that sits flush with the ground plane and a validated test site matter just as much, and a careless move can undo all three.

Pyramidal absorbers crush easily and ferrite tiles crack. A flush-mounted turntable needs a properly prepared pit at the new site. And if panel joints and door gaskets aren't brought back to their original tightness, shielding effectiveness drops.

So we run a relocation as a reinstallation project, not a haulage job. We measure the chamber before it moves, document every part as it comes down, rebuild it at the new site and repeat the same measurements. You end up with a side-by-side report you can put straight into your accreditation file.

Baseline Test

Current performance is recorded.

Absorber Map

Every absorber position is documented.

Precise Rebuild

Turntable, mast and door are re-set.

Re-Validation

NSA, SVSWR and shielding re-tested.

What we move

Chambers We Relocate

Every chamber type has its own critical points in a move. We build the plan around your chamber and the conditions at the new site.

Semi-Anechoic EMC Chamber

SAC-3, SAC-5 and SAC-10 chambers

NSA · SVSWRre-validation
  • Ferrite and hybrid absorber removal
  • Flush turntable and ground plane
  • Field uniformity calibration
Get a Quote

Fully Anechoic Chamber

OTA and broadband measurement rooms

Floor includedabsorber lining
  • Floor absorbers removed and stored
  • Positioner relocation
  • Quiet-zone check
Get a Quote
Precision Move

Antenna Measurement Chamber

Far-field, near-field and compact range

Alignmentre-calibration
  • Reflector and scanner protection
  • Positioner alignment
  • Quiet-zone verification
Get a Quote

CISPR 25 / MIL-STD Chamber

Chambers with ground-plane test benches

Test benchbonding continuity
  • Ground-plane bonding
  • Filtered power entries
  • LISN and bench layout
Get a Quote
Antenna chamber relocation

Moving an Antenna Chamber Takes Millimeter Precision

An antenna measurement range is only as good as its alignment. The compact-range reflector, near-field scanner and positioner all have to return to the same geometry at the new site; otherwise the patterns you measure will no longer match your reference data.

We crate reflectors so nothing ever touches the surface and remove phase-stable RF cables without exceeding their bend radius. At the new site we re-level and re-align positioners and scanners, then check the quiet zone and the full measurement chain with a standard gain horn before the range goes back into service.

  • Compact-range reflector

    Crated so the surface is never touched.

  • Near-field scanner

    Planarity re-set at the new site.

  • Positioner

    Axes re-aligned, reference points re-taken.

  • Phase-stable cables

    Removed and shipped within their bend radius.

  • Quiet zone

    Reflectivity measured again.

  • Reference antenna check

    System verified with a standard gain horn.

Process

A Smooth Move in Six Steps

  1. 1

    Survey and Baseline

    We inspect both sites and record current performance.

  2. 2

    Site Preparation

    Turntable pit, floor, power and HVAC are made ready.

  3. 3

    Documented Teardown

    Parts are numbered and photographed as they come down.

  4. 4

    Protected Transport

    Fragile parts travel in purpose-built packaging.

  5. 5

    Rebuild and Renewal

    Gaskets and damaged absorbers are replaced.

  6. 6

    Validation and Report

    Baseline tests are repeated and reported.

For accredited labs

Keep the Accreditation Gap Short

For a lab testing under ISO/IEC 17025, moving a chamber is more than a physical job. The existing site validation no longer applies at the new location, and the chamber must be validated again before accredited testing can resume.

We plan the move around your accreditation calendar. We repeat the baseline measurements at the same points with the same method and give you a report that sets the results side by side, so you have the evidence your accreditation body will ask for.

  • Side-by-side report

    Before and after results in one table.

  • Same method, same points

    Results are directly comparable.

  • Calibrated equipment

    Traceable calibration certificates.

  • Planned downtime

    Scheduled around your test calendar.

Technical specifications

Typical Scope of Service

Scope depends on your chamber type and the condition of the new site. We confirm it in writing in the quote after the site survey.

ScopeTeardown, packing, transport, rebuild
Chamber typesSAC, FAR, antenna and OTA chambers
TestingShielding, NSA, SVSWR, field uniformity
RenewalGaskets, damaged absorbers, filters
DocumentationSide-by-side before and after report
CoverageWorldwide, customs included
Frequently asked questions

Frequently Asked Questions About Chamber Relocation

If your question isn't answered here, ask our engineer directly.

PhoneWhatsApp

Can you move a chamber built by another manufacturer?

Yes. During the survey we inspect the panel system, absorber type and equipment, then report on whether the chamber can be moved and which parts will need renewing.

Can the absorbers be reused?

Sound absorbers are reused. Because some ferrite tiles crack during removal and older foam absorbers deteriorate over time, we identify which ones need replacing during the survey.

Does the chamber need to be re-validated after the move?

Yes. A move changes the chamber's geometry and ground-plane bonding. The chamber shouldn't be used as a test site until NSA, SVSWR and shielding measurements have been repeated.

Can the chamber be rebuilt to a different size?

With modular chambers, yes. A size change affects absorber layout and validation results, so we model it at the design stage.

How long does a relocation take?

It depends on the chamber size, distance and how ready the new site is. After the survey we provide a schedule covering teardown, transport, rebuild and testing.

Can we upgrade the chamber during the move?

Yes, and it's the ideal time to do it. Absorber renewal, frequency range extension or new penetrations can all be planned alongside the move.

Do you handle international relocations?

Yes. We plan packing, shipping and customs, and our own team carries out the rebuild and validation in the new country.