Absorber Materials and Fire Safety in Anechoic Chambers

The fire risk of foam absorbers used in anechoic chambers, flame-retardant standards and suitable detection and suppression measures for the chamber.

Anechoic chambers carry a particular fire risk because of the absorber materials inside them. The foam absorbers covering most of the chamber are made of carbon-loaded polymer materials and are combustible by nature. Moreover, high-power radio-frequency tests are carried out in these chambers, and absorbers convert energy into heat in these tests. The combination of these two factors makes fire safety an integral part of anechoic chamber design.

In this article we explain where fire risk in anechoic chambers comes from, how fire-retardant absorbers are chosen, how detection and suppression systems are designed, the precautions to take in high-power tests and what to do in daily operation to reduce fire risk.

Where Does the Risk Come From?

Fire risk in anechoic chambers has two main sources. The first is the absorber material itself. Foam absorbers are made of carbon-loaded polyurethane or similar materials to absorb incoming radio-frequency energy. Even when treated with fire-retardant additives, these materials can ignite and burn if given enough energy.

The second source is high-power immunity tests. In these tests hundreds, sometimes thousands, of watts are fed into the chamber, and most of this energy turns into heat in the absorbers. The absorbers right in front of the antenna can heat up noticeably, especially in long, high-level tests. A faulty antenna connection, a metal part brought into the chamber or an unexpected reflection can increase the risk by creating local hot spots.

Fire-Retardant Absorbers

Foam absorbers used in anechoic chambers are made with fire-retardant additives, and their fire behaviour is assessed with standard tests. These tests measure how quickly the material ignites when exposed to a flame, how fast the flame spreads and whether the material self-extinguishes when the flame source is removed. The material's performance in these tests must be evaluated when choosing absorbers.

Test reports showing the material's fire behaviour should be requested from the absorber manufacturer. These reports are part of the chamber's fire safety design and of compliance with local regulations. The absorbers' behaviour under high power, that is how long they can withstand a given power density, also matters. This information is used to set the power limits of tests to be carried out in the chamber.

  • Resistance to ignition by a flame source
  • Flame spread rate
  • Self-extinguishing behaviour
  • Withstand to high power density

Detection Systems

Early detection of fire in anechoic chambers is critical, because once absorbers ignite, fire can spread quickly and produce dense smoke. The chamber's large volume and absorber-lined surfaces can reduce the effectiveness of conventional smoke detectors. Aspirating smoke detection systems are therefore usually preferred in anechoic chambers.

These systems continuously draw air samples from inside the chamber through pipes and analyse them in a sensitive detector outside the chamber. This reduces the need to place electronic detectors inside the chamber, and even very early-stage smoke can be detected. Sampling pipes enter the chamber through waveguide penetrations so as not to compromise shielding. We explain detection systems in detail in our article on fire detection in shielded rooms.

Suppression Systems

Choosing a suppression system for anechoic chambers requires careful evaluation. Water-based sprinkler systems can be used, but the damage water would do to absorbers and expensive equipment in the chamber must be considered. Wet absorbers usually have to be replaced. For this reason some facilities prefer gaseous suppression systems that do not damage equipment.

For gaseous suppression to be effective, the chamber must be sufficiently airtight and the agent concentration must be maintained for a certain time. Shielded chambers usually have a suitable structure in this respect. The suppression system should be chosen together with the building's fire consultant, the local competent authorities and the chamber designer. Suppression pipes also enter the chamber through special penetrations so as not to compromise shielding.

Precautions in High-Power Tests

High-power immunity tests are the most important source of fire risk in anechoic chambers. Special precautions should therefore be taken for these tests. It should be verified that the absorbers in front of the antenna can withstand the power density to be applied. If necessary, absorbers with higher power handling are placed directly in front of the antenna.

The temperature of absorbers can be monitored during the test; some laboratories use thermal cameras for this. Long high-power tests can be interrupted at intervals to let absorbers cool. Amplifier, cable and antenna connections should also be checked before every test; a loose connection or damaged cable can cause unexpected heating.

Operational Precautions

Fire safety is provided not only by systems but also by daily operation. Unnecessary combustible materials, such as packaging cardboard, foam or paper, should be kept out of the chamber. Packaging of products under test should be removed before testing and kept outside the chamber.

The physical condition of absorbers should be checked regularly. Damaged, crushed or soiled absorbers can adversely affect both measurement performance and fire behaviour. Staff should be trained regularly on emergency procedures, fire detection alarms and how the suppression system works. These checks should be part of your annual maintenance list.

Planning at the Design Stage

Fire safety should be addressed from the very start of anechoic chamber design. Topics such as absorber selection, detection and suppression systems, emergency lighting, escape routes and doors always being openable from the inside should be planned together with the chamber's overall design. Adding them later is both costly and risky for shielding performance.

Local fire regulations and the building's overall fire safety concept should be taken into account in chamber design. It is therefore recommended to involve the building's fire consultant and the relevant competent authorities early in the design process. A correctly planned anechoic chamber gives trouble-free service for many years in terms of both measurement performance and safety. For our chamber options, see our semi-anechoic chamber and fully anechoic room pages.

Frequently Asked Questions

Do absorbers ignite spontaneously?

Not under normal conditions. The risk arises from overheating in high-power tests or contact with a flame source; fire-retardant absorbers reduce this risk.

Does a fire detector affect the measurement?

Electronic detectors placed inside the chamber can. That is why systems that sample air from outside the chamber through pipes are usually preferred.

Can sprinklers be used?

They can, but the damage water would do to absorbers and equipment must be considered. Some facilities prefer gaseous suppression systems.

How is the fire behaviour of absorbers documented?

With test reports from the absorber manufacturer showing the material's performance in standard fire tests.

What should be done in high-power tests?

The absorbers' power handling should be verified, the test never left unattended, connections checked and the detection system linked to the amplifier.

Do damaged absorbers increase fire risk?

Damaged or soiled absorbers can adversely affect both measurement performance and fire behaviour; they should be checked regularly and replaced.