The setup of IEC 61000-4-4, which measures immunity to fast pulse bursts created by relay and contactor switching, and the most common problems.
When a large contactor opens in a factory, when a motor coil is de-energised or when relay contacts separate, very short but very fast-rising voltage pulses appear on the power line. These pulses do not come alone but in bursts, one after another, and reach other equipment connected to the same line.
IEC 61000-4-4 is the basic standard used to measure the immunity of equipment to such fast transient bursts, that is EFT/burst events. In this article we explain where these pulses come from, how the test is applied, the test levels and performance criteria, why products fail this test and what to watch for in the test environment.
Fast transients appear when inductive loads are switched. As the contacts of a relay, contactor or switch separate, the energy stored in the coil causes small sparks between the contacts. These sparks form and die out repeatedly until the contacts are fully apart, and each produces a very fast-rising voltage pulse on the line. The result is a burst of pulses lasting milliseconds.
These pulses reach all equipment connected to the same power line by conduction; they also couple to parallel cables capacitively and inductively. So a device can be exposed to these pulses through its communication and control cables as well as directly through its power line. Industrial environments are where such events are most frequent and most severe.
IEC 61000-4-4 represents this complex real-life event with a standard test signal. Each pulse has a rise time of 5 nanoseconds and a time to half value of 50 nanoseconds. These pulses are lined up in a burst at a set repetition frequency, commonly 5 kHz or 100 kHz, and bursts repeat every 300 milliseconds.
Because the pulses rise very fast, their energy is spread over a wide frequency range. The EFT test therefore also tests a device's immunity to high-frequency noise. The energy of the pulses is very low compared with surge pulses; EFT usually causes temporary malfunctions and incorrect operation rather than permanent damage. We explain the surge test in our article on the IEC 61000-4-5 surge test.
On power lines, pulses are applied through a coupling/decoupling network (CDN) between each line and earth. The CDN transfers the pulse to the line under test while preventing it from returning to the mains. For signal, communication and control cables, a capacitive coupling clamp is used; the cable is passed through the clamp and the pulse is coupled onto it capacitively.
The test is carried out on a reference ground plane in a defined layout. Tabletop equipment is placed on an insulating support above the plane, and cable lengths and heights above the plane are set according to the standard. Pulses are applied for at least one minute at each polarity, and the device's behaviour is monitored throughout.
The standard defines separate levels for power and signal lines. For power lines the levels are 0.5, 1, 2 and 4 kV; for signal lines they are half these values, 0.25, 0.5, 1 and 2 kV. For residential and commercial environments, the generic standard requires 1 kV on the AC power input and 0.5 kV on signal lines. For industrial environments these rise to 2 kV and 1 kV respectively.
Criterion B is usually required in the EFT test: the device may show a temporary degradation during bursts but must return to normal operation by itself when the test ends. Loss of settings, a restart requiring user intervention or an output changing unintentionally is considered a failure in most standards. Acceptable behaviour should be defined in advance in the test plan.
Most EFT failures come from the fast rise of the pulse. This fast change can easily get past input filters and cause brief fluctuations in reference voltages on the board. The most common symptoms are the microcontroller resetting, data errors on communication lines, drift in analogue measurements and false detections in touch interfaces.
The common cause of these problems is usually common-mode noise reaching the inside of the board. Insufficient common-mode filtering, long and thin ground connections, a poor connection between housing and board and a reset line exposed to noise are typical causes of failure. We have collected the points where tests fail most often in our article on reasons for failing EMC tests.
The basis of EFT immunity is diverting the pulse's energy to the housing or ground plane before it enters the board. At the power input, common-mode chokes and Y capacitors suppress most of the pulse. Placing these components close to the connector and bonding them to the housing with short, wide connections directly determines their performance.
On communication and control lines, common-mode chokes, ferrite components and suitable filter capacitors are used. Shielded cables provide effective protection when their shields are bonded peripherally to the housing at the connector. On the software side, watchdog timers, retry mechanisms for communication errors and software filtering of analogue measurements limit the remaining effects. We explain board design rules in our article on EMC in PCB design.
A shielded or anechoic room is not mandatory for the EFT test; it can be done on a test bench with a reference ground plane. However, the high-frequency noise produced by the pulses can affect nearby measurement instruments and computers. It is therefore recommended that the test area be kept away from sensitive equipment and that the connections used to monitor the device be protected against noise.
Most electronics manufacturers carry out EFT testing together with ESD and surge testing on a bench they set up in-house. This approach finds problems early, before the certification test. Radiated tests need a separate EMC test chamber. You can find our solutions for electronics manufacturers on our electronics manufacturing page.
No. EFT represents low-energy but very fast, repetitive bursts; surge represents single but high-energy pulses. The two tests are carried out to separate standards.
At least one minute is applied for each polarity at each port. Total time depends on the number of ports tested.
Under the usually required criterion B, the device must recover by itself. A restart requiring user intervention is considered a failure in most standards.
AC and DC power lines and signal, communication and control cables exceeding a certain length are tested. The exact scope is set by the standard applying to the product.
For industrial environments, the generic standard requires 2 kV on the AC power input and 1 kV on signal lines.
No. The test can be done on a bench with a reference ground plane; however, keeping sensitive equipment away from the test area is recommended.
Related Solutions
Your free site survey and quote will be ready within 24 hours.
GTEM cells used for emission and immunity pre-testing of small products in space-limited labs, with their advantages and limits.
The EMC standards electric vehicle chargers must meet, the challenges of high-power testing and the test chamber requirements.
The points where electronic products most often fail EMC certification, and simple measures you can take at the design stage, from an engineer's view.