The Radio Equipment Directive (RED) and EMC for Wireless Products
Which directive covers products with Wi-Fi, Bluetooth or cellular modules in Europe, and how their EMC testing changes as a result.
The FCC Part 15 rules electronics sold in the US must follow, the Class A and Class B split, and how it differs from European testing.
Many manufacturers developing a CE-marked product for the European market target the US market next. In the US, the electromagnetic emissions of electronic products are regulated by the rules of the Federal Communications Commission (FCC), and the best-known part of these rules is Part 15. Although it looks similar to European requirements, there are important differences in approval routes, responsibilities and some technical details.
In this article we explain which products FCC Part 15 covers, the Class A and Class B distinction, the different approval routes for unintentional and intentional radiators, measurement methods, differences from European requirements and how testing for both markets can be planned together.
FCC Part 15 regulates devices that emit radio-frequency energy without a licence. These devices fall into two main groups. Unintentional radiators emit radio-frequency energy as a by-product of their function; computers, monitors, printers and almost every electronic product containing digital circuits fall into this group. Intentional radiators are devices that deliberately emit radio signals, such as Wi-Fi, Bluetooth or other wireless links.
Part 15 sets limits on the emissions of these devices and aims to prevent them causing harmful interference to licensed radio services. An important difference is that Part 15 generally does not define immunity tests; that is, for most product groups the FCC does not regulate how immune a product is to outside interference. But this does not mean immunity is unimportant; customers and market expectations may set their own requirements.
The FCC divides digital devices into two classes according to their environment of use. Class A covers devices marketed for use in commercial, industrial or business environments. Class B covers devices that may be used in homes and has stricter limits. If a product could be used in homes, it must meet Class B limits.
The user manual of Class A devices must contain a specific warning that the device may cause interference in a residential environment. Class B devices also carry a text informing the user. The content of these texts is defined in FCC rules. The class chosen must be consistent with how the product is marketed; a product sold to home users cannot be assessed as Class A.
For most unintentional radiators, the approval route is the supplier's declaration of conformity (SDoC). On this route the manufacturer or the responsible party in the US has the product tested, declares conformity and keeps the test records. The product is not registered separately with the FCC, but the required information must appear on the product and in its documentation. Designating a responsible party located in the US is an important requirement of this route.
Intentional radiators, products with wireless connectivity, require certification. In this process the product is tested in an FCC-recognised laboratory and the results are submitted to an authorised certification body (TCB). The approved product receives an FCC ID, which appears on the product. Using a pre-certified module can simplify this process, but the end product must still be assessed separately as an unintentional radiator.
Emission measurements under FCC Part 15 are made with the methods defined in the ANSI C63 series of standards. ANSI C63.4 is the main reference for unintentional radiators and ANSI C63.10 for intentional radiators. These standards define site validation, test setup, measurement distances and detectors.
As in Europe, measurements are made in a validated semi-anechoic chamber or on an open area test site. The measurement distance is usually 3 m or 10 m. Above 1 GHz, average and peak detectors are used. Small differences between measurement methods can lead to differences in the results for the same product in the two markets. For test infrastructure, see our semi-anechoic chamber page.
No. FCC tests can be carried out in FCC-recognised laboratories, which exist in many countries around the world. For the certification of intentional radiators, tests must be carried out in an FCC-recognised laboratory. For unintentional radiators on the SDoC route, requirements for the test laboratory are more flexible, but choosing a laboratory that measures reliably and accurately is important in every case.
Manufacturers with their own test infrastructure can carry out a significant part of the tests needed for Europe and the US in their own facilities. Pre-tests in particular are very useful for assessing both markets' limits together. Designing a product to meet both markets' limits at once is much more economical than making changes later.
For manufacturers targeting both the European and US markets, the most efficient approach is to prepare the test plan from the start to cover both markets. Emission tests can be carried out in a single test programme taking into account both markets' measurement methods and limits. The immunity tests needed for Europe are planned separately, because the FCC generally does not require them.
For wireless products, the differences between the two markets are more pronounced. Frequency bands, power limits and test methods may differ, so radio performance tests are usually carried out separately for each market. We explain European requirements for wireless products in our article on RED. We cover how to prepare the test plan in our article on your EMC test plan.
Under FCC rules, changes made to an approved product may require reassessment if they could affect the product's emission characteristics. For example, changes to the board layout, clock frequencies, power supply or housing can change emissions. The effect of the change should be assessed with new measurements and records updated.
The information required by FCC rules must appear on the product and in user documentation. This information varies with the approval route: it includes the FCC ID for certified products and compliance information for products approved through SDoC. Labelling requirements should be taken into account early in product design. For large-scale test infrastructure options, see our SAC-10 page.
No. Tests can be carried out in FCC-recognised laboratories, which exist in many countries around the world.
They are similar, but there are differences in the details of limits and measurement methods. A test result for one market is not automatically valid for the other.
FCC Part 15 generally does not define immunity tests. But immunity tests may be needed for customer requirements and other markets.
The supplier's declaration of conformity. On this route, used for most unintentional radiators, the manufacturer or responsible party in the US declares the product's conformity and keeps the test records.
The module simplifies the radio part, but the end product's emission assessment as an unintentional radiator is still needed.
Yes, if the change could affect emission characteristics. Its effect should be assessed with new measurements.
Your free site survey and quote will be ready within 24 hours.
Which directive covers products with Wi-Fi, Bluetooth or cellular modules in Europe, and how their EMC testing changes as a result.
The chamber, equipment and validation steps for organizations that want to set up their own EMC lab and gain ISO/IEC 17025 accreditation.
What an EMC test plan should contain before you go to the certification lab: standards, operating modes and performance criteria.